Skoči na glavni sadržaj

Izvorni znanstveni članak

https://doi.org/https://doi.org/10.5513/JCEA01/25.4.4071

The effect of the amount of fat content in milk extender on ram sperm motility parameters during the storage of 5 °C for 72 h and comparison with the other semen extenders

Alena BÚDOVÁ ; University of South Bohemia in České Budějovice, Faculty of Agriculture and Technology, Department of Animal Husbandry Sciences, Studentská 1668, 370 05 České Budějovice, Czech Republic
Aleš LISNER ; University of South Bohemia in České Budějovice, Faculty of Science, Department of Botany, Branišovská 1760, 370 05 České Budějovice, Czech Republic
Ladislav STRNAD ; University of South Bohemia in České Budějovice, Faculty of Agriculture and Technology, Department of Animal Husbandry Sciences, Studentská 1668, 370 05 České Budějovice, Czech Republic
Jana VOKROUHLÍKOVÁ ; University of South Bohemia in České Budějovice, Faculty of Agriculture and Technology, Department of Animal Husbandry Sciences, Studentská 1668, 370 05 České Budějovice, Czech Republic
Kateřina KUMBLE ; University of South Bohemia in České Budějovice, Faculty of Agriculture and Technology, Department of Animal Husbandry Sciences, Studentská 1668, 370 05 České Budějovice, Czech Republic
Jan BERAN ; University of South Bohemia in České Budějovice, Faculty of Agriculture and Technology, Department of Animal Husbandry Sciences, Studentská 1668, 370 05 České Budějovice, Czech Republic *

* Dopisni autor.


Puni tekst: engleski pdf 1.030 Kb

str. 884-891

preuzimanja: 0

citiraj


Sažetak

The objective of this study was to evaluate the effect of the amount of fat content in milk extender and comparison with other semen extender and evaluate their effect on ram sperm motility and kinematic parameters during the liquid storage of 5 °C for an evaluation period of 72 hours. The semen samples were collected from three Šumava sheep rams (4 years old) using an artificial vagina and were diluted by physiological solution, 0.5% fat milk, 1.5% fat milk and AndroMed® extenders with a dilution 1:100. Motility and kinematic parameters were evaluated using the CASA (Computer-assisted sperm analysis) at regular time intervals of 0, 12, 24, 36, 48 and 72 hours after sperm collection. The effect of extenders on motility and kinematic parameters varied significantly among each other. The temporal decrease rate in sperm quality differed between extenders. Physiological solution can be used on the farm for insemination within 24 hours of collection when the sperm quality is still very good. Milk diluent with 0.5% fat has better sperm motility parameters than milk diluent with 1.5% fat, but of all the extenders tested, the milk extenders had the worst quality. The best diluent tested was AndroMed®, which showed good values of motility parameters even after 72 hours of storage at 5 °C.

Ključne riječi

ram ejaculate quality; CASA; motility; kinematic parameters; artificial insemination

Hrčak ID:

324571

URI

https://hrcak.srce.hr/324571

Datum izdavanja:

23.12.2024.

Podaci na drugim jezicima: češki

Posjeta: 0 *