Performance evaluation of thermal bridge mitigation strategies against the mould growth

Domagoj Tkalčić
Bojan Milovanović
Mergim Gaši
Ivana Banjad Pečur


Puni tekst: hrvatski pdf 4.081 Kb

str. 151-170

preuzimanja: 0

citiraj

Puni tekst: engleski pdf 4.076 Kb

str. 151-170

preuzimanja: 0

citiraj


Sažetak

This study investigates mould/fungi growth risk on two different approaches of thermal bridge mitigation. Thermally insulated balconies and thermally broken balconies in Zero Emission Building (ZEB) are reviewed. Linear thermal transmittance (ψ - value), interior surface temperature and mould/fungi growth risk for five balcony designs is performed. Each design has three variations, two of which have thermal insulation wrap, and a thermal break replacing insulation. Results show thermal breaks outperform all variations. This contradicts the common practice of using thermal insulation wrap. The study also emphasizes EN ISO 13788 inadequacy as comprehensive HAM models are available.

Ključne riječi

thermal bridges; thermal break; surface temperature; temperature factor; mould growth; ZEB; balcony slab