Skoči na glavni sadržaj

Izvorni znanstveni članak

Plasma diagnostics of high-pressure sodium-cadmium and sodium-mercury discharges

Davorka Azinović ; Institute of Physics of the University, POB 304, 41000 Zagreb
Jadranka Rukavina ; TEŽ, Folnegovićeva 10, 41000 Zagreb
Goran Pichler ; Institute of Physics of the University, POB 304, 41000 Zagreb
Damir Veža ; Institute of Physics of the University, POB 304, 41000 Zagreb


Puni tekst: engleski pdf 6.170 Kb

verzije

str. 469-479

preuzimanja: 138

citiraj


Sažetak

We report measurements of electron temperature and pressures of neutral particles in plasmas of high-pressure Na-Hg-Xe or Na-Cd-Xe arcs. We applied the standard plasma diagnostic techniques developed for the Na-Hg-Xe discharge to the new Na-Cd-Xe discharge lamp. Electron temperature has been calculated from the shape of the sodium recombination continuum at 408 nm in the case of Na-Cd-Xe lamp. The results are compared with the temperature obtained from the shape of self-reversed sodium lines at 568.2 nm and 568. 8 nm. Sodium, mercury and cadmium vapour pressures have been derived from the separation of maxima of self-reversed sodium resonance line.

Ključne riječi

Hrčak ID:

332244

URI

https://hrcak.srce.hr/332244

Datum izdavanja:

6.8.1990.

Podaci na drugim jezicima: hrvatski

Posjeta: 401 *