Flexural Strength of E - glass Fiber Reinforced Dental Polymer and Dental High Impact Strength Resin

Denis VOJVODIĆ ; Stomatološki fakultet, Sveučilište u Zagrebu, Zagreb, Hrvatska
Franjo MATEJIČEK ; Strojarski fakultet u Slavonskom Brodu, Sveučilište J. J. Strossmayera u Osijeku, Osijek, Hrvatska
Zdravko SCHAUPERL ; Fakultet strojarstva i brodogradnje u Zagrebu, Sveučilište u Zagrebu, Zagreb, Hrvatska
Ketij MEHULIĆ ; Stomatološki fakultet, Sveučilište u Zagrebu, Zagreb, Hrvatska
Ivana BAGIĆ-ČUKOVIĆ ; Stomatološki fakultet, Sveučilište u Zagrebu, Zagreb, Hrvatska
Sanja ŠEGOVIĆ ; Stomatološki fakultet, Sveučilište u Zagrebu, Zagreb, Hrvatska


Puni tekst: engleski pdf 2.337 Kb

str. 221-230

preuzimanja: 1.769

citiraj


Sažetak

Fractures of denture base polymer material are one of the most frequent reasons for repair of removable dentures. Therefore, there is a continuous effort to strengthen them, and polymer materials of high resistance to fracture are being developed. The aim of this study was to determine the flexural strength of denture base polymers (pressure-heat polymerizing and auto polymerizing) reinforced with E -glass fibers and high impact strength resin (injectional polymerization) material using the “short beam” method. Specimens were tested after polymerization and after artificial ageing performed by storage at 37 ºC temperature during 28 days and thermocycling. Microscopic examination was performed to determine the quality of bonding between glass fibers and matrix. The study showed significantly higher values of flexural strength (130.1-163.88 MPa) of glass fiber reinforced specimens compared to the un-reinforced specimens (91.77 – 122.75 MPa) – control group, matching those of high impact strength resin (145.67 MPa). Between the groups of samples tested after polymerization and storage in water at 37 ºC during 28 days there was no statistically significant difference in flexural strength values while samples tested after thermocycling unexpectedly revealed significantly higher values. Fiber reinforced materials and high impact strength resin revealed similar results of flexural strength both being acceptable for clinical use. Obtained results suggest that the increase of temperature (during thermocycling) had the effect of prolonged polymerization which resulted in a decrease of residual monomer volume, enhancing polymer mechanical properties.

Ključne riječi

Dental materials; Flexural strength; Polymers