Skoči na glavni sadržaj

Izvorni znanstveni članak

Stability analysis for masonry-arch structures and vaulted structures

Mirjana Bošnjak-Klečina
Silva Lozančić


Puni tekst: hrvatski pdf 1.619 Kb

str. 409-421

preuzimanja: 2.459

citiraj


Sažetak

The authors analyse cross vault of the Sts. Peter and Paul Church in Osijek, cross vault of the Đakovo Cathedral, and barrel vault of the Sts. Philip and Jacob church in Vukovar. The following actions are considered: permanent load, change in structural system, and increase in horizontal spacing between the supports. Two approaches are used. In the first approach, the analysis results in stress values. The second is used to determine the structural failure model for the maximum value of increase in horizontal spacing between supports, and for minimum horizontal acceleration of soil due to seismic action.

Ključne riječi

masonry structures; cross vault; barrel vault; structural stability; permanent load; increase in horizontal spacing between supports

Hrčak ID:

55576

URI

https://hrcak.srce.hr/55576

Datum izdavanja:

27.5.2010.

Podaci na drugim jezicima: hrvatski

Posjeta: 3.325 *