Skip to the main content

Preliminary communication

Optimization of Timely Replacement of Sectional Furnace Refractory Lining

L. Lazić
P. Jelić
S. Pavlenić


Full text: english pdf 296 Kb

page 313-316

downloads: 702

cite


Abstract

The goal of the study is to establish the influence of temporal wearing of refractory lining on energy losses of the furnaces by conducting heat through the furnaces walls. Object of the study were sectional furnaces, type SELAS, situated in the seam tubes production line in Željezara Sisak, Croatia. In order to reduce production costs, it was attempted to define the timely replacement of refractory lining by the criteria of comparing the costs resulted by heat loss through the furnace lining with the costs of refractory lining replacement. Data for the calculation of heat losses was obtained by use of the infrared camera.

Keywords

Hrčak ID:

128571

URI

https://hrcak.srce.hr/128571

Publication date:

1.10.2002.

Article data in other languages: croatian

Visits: 1.624 *