Skip to the main content

Original scientific paper

https://doi.org/10.11613/BM.2015.037

Specimen rejection in laboratory medicine: Necessary for patient safety?

Zeliha Gunnur Dikmen ; Hacettepe University Faculty of Medicine, Department of Medical Biochemistry and Hacettepe University Hospitals, Clinical Pathology Laboratory, Ankara, Turkey
Asli Pinar ; Hacettepe University Faculty of Medicine, Department of Medical Biochemistry and Hacettepe University Hospitals, Clinical Pathology Laboratory, Ankara, Turkey
Filiz Akbiyik ; Hacettepe University Faculty of Medicine, Department of Medical Biochemistry and Hacettepe University Hospitals, Clinical Pathology Laboratory, Ankara, Turkey


Full text: english pdf 272 Kb

page 377-385

downloads: 1.373

cite


Abstract


Introduction: The emergency laboratory in Hacettepe University Hospitals receives specimens from emergency departments (EDs), inpatient services and intensive care units (ICUs). The samples are accepted according to the rejection criteria of the laboratory. In this study, we aimed to evaluate the sample rejection ratios according to the types of pre-preanalytical errors and collection areas.
Materials and methods: The samples sent to the emergency laboratory were recorded during 12 months between January to December, 2013 in which 453,171 samples were received and 27,067 specimens were rejected.
Results: Rejection ratios was 2.5% for biochemistry tests, 3.2% for complete blood count (CBC), 9.8% for blood gases, 9.2% for urine analysis, 13.3% for coagulation tests, 12.8% for therapeutic drug monitoring, 3.5% for cardiac markers and 12% for hormone tests. The most frequent rejection reasons were fibrin clots (28%) and inadequate volume (9%) for biochemical tests. Clotted samples (35%) and inadequate volume (13%) were the major causes for coagulation tests, blood gas analyses and CBC. The ratio of rejected specimens was higher in the EDs (40%) compared to ICUs (30%) and inpatient services (28%). The highest rejection ratio was observed in neurology ICU (14%) among the ICUs and internal medicine inpatient service (10%) within inpatient clinics.
Conclusions: We detected an overall specimen rejection rate of 6% in emergency laboratory. By documentation of rejected samples and periodic training of healthcare personnel, we expect to decrease sample rejection ratios below 2%, improve total quality management of the emergency laboratory and promote patient safety

Keywords

clinical laboratory services; total quality management; patient safety; preanalytical phase; preanalytical error

Hrčak ID:

148681

URI

https://hrcak.srce.hr/148681

Publication date:

15.10.2015.

Visits: 3.523 *