Skip to the main content

Preliminary communication

https://doi.org/10.14256/JCE.1133.2014

Performance evaluation of reinforced concrete buildings with softer ground floors

R. Tuğrul Erdem


Full text: croatian pdf 688 Kb

page 39-49

downloads: 950

cite

Full text: english pdf 2.126 Kb

page 39-49

downloads: 1.078

cite


Abstract

Determination of seismic performance is a significant task in the performance-based seismic analysis of structures. The consistency between analysis results obtained according to various codes is highly significant for seismic evaluation of structures. Non-linear performance of three reinforced concrete buildings having a soft storey irregularity is studied based on the finite elements analysis according to FEMA-356, FEMA-440, and Turkish Earthquake Code - 2007. Damage situations, modal properties, storey drift ratios, and global performance levels are comparatively presented for each structure, and appropriate suggestions are given.

Keywords

finite elements analysis; irregular structures; non-linear procedures; seismic performance