Skip to the main content

Original scientific paper

https://doi.org/10.11613/BM.2017.015

Proficiency testing of maternal serum prenatal screening in second trimester in China, 2015

Xiaoyan Zhang ; National Center for Clinical Laboratories/Beijing Engineering Research Center of Laboratory Medicine, Beijing Hospital, Beijing, P.R. China
Wei Wang ; National Center for Clinical Laboratories/Beijing Engineering Research Center of Laboratory Medicine, Beijing Hospital, Beijing, P.R. China
Falin He ; National Center for Clinical Laboratories/Beijing Engineering Research Center of Laboratory Medicine, Beijing Hospital, Beijing, P.R. China
Kun Zhong ; National Center for Clinical Laboratories/Beijing Engineering Research Center of Laboratory Medicine, Beijing Hospital, Beijing, P.R. China
Shuai Yuan ; National Center for Clinical Laboratories/Beijing Engineering Research Center of Laboratory Medicine, Beijing Hospital, Beijing, P.R. China
Zhiguo Wang ; National Center for Clinical Laboratories/Beijing Engineering Research Center of Laboratory Medicine, Beijing Hospital, Beijing, P.R. China


Full text: english pdf 251 Kb

page 114-121

downloads: 413

cite


Abstract

Introduction: Prenatal screening and diagnosis is important for the detection of birth defects and genetic diseases. The nationwide proficiency testing (PT) of maternal serum prenatal screening in second trimester in China has been launched since 2003 and partly reflected the performance of screening laboratories. This study analysed the 2015 PT results to examine the performance of clinical laboratories and different platforms.
Materials and methods: Fifteen lyophilized samples with different concentrations divided into three panels, were distributed to 613 clinical laboratories in 2015. Acceptable performance was defined as scores more than 80% of acceptable responses with the evaluation criterion of ± 30%. The robust coefficient of variation (CV) was also analysed. Chi-square (?2) test was used to compare the acceptable performance while Kruskal-Wallis test and Mann-Whitney test were applied to compare the robust CV among analytes and mainstream platforms.
Results: Overall, 605, 61, 214, 416, 303 laboratories submitted effective results for alpha fetoprotein (AFP), total human chorionic gonadotropin (t-hCG), ß-hCG, unconjugated estriol (uE3) and free ß-hCG. The acceptable performances of AFP (µg/L), AFP (KIU/L), t-hCG, ß-hCG, uE3, and free ß-hCG were 98.45%, 99.24%, 95.58%, 98.72%, 94.50%, and 98.66%, respectively. The ?2 test indicated significant differences existed in the acceptable performances among different analytes and platforms for uE3. Kruskal-Wallis test and Mann-Whitney test suggested the robust CV differed significantly in different analytes and platforms.
Conclusions: The majority of results were acceptable. However, further effort is needed to achieve the standardization and harmonization among analytes and various platforms, particularly for uE3.

Keywords

maternal serum screening tests; proficiency testing; pregnancy trimester

Hrčak ID:

176474

URI

https://hrcak.srce.hr/176474

Publication date:

15.2.2017.

Visits: 1.258 *