Skip to the main content

Original scientific paper

https://doi.org/10.37798/202170144

Maintenance of Filter at The Gas Turbine Compressor Intake and Electric Transformer Connector Based on Operational Reliability

Josip Ivankić ; HEP Trade Ltd
Deni Ćetković ; HEP—Distribution system operator
Dario Matika ; Faculty of Engineering, University of Rijeka


Full text: english pdf 834 Kb

page 22-28

downloads: 299

cite


Abstract

The article analyzes the operational reliability of filter on the gas turbine compressor intake and the operational reliability of electric transformer
connector. Empirical data (statistical sample) were collected to determine the failure density function f (t), the hazard function λ (t), and the expected
value of mean time to failure MTTF. The numerical model was created in the Minitab 19 software tool. The Anderson-Darling test was used to accept
or reject the hypothesi

Keywords

compressor, filter, probability distribution, reliability

Hrčak ID:

261852

URI

https://hrcak.srce.hr/261852

Publication date:

15.2.2021.

Visits: 874 *