Skip to the main content

Meeting abstract

https://doi.org/10.15836/ccar2023.111

Mitral annulus disjunction and Barlow’s disease in a young male patient

Anja Mandrapa orcid id orcid.org/0009-0002-3416-5906 ; University Hospital of Split, Split, Croatia
Paula Radić orcid id orcid.org/0000-0002-7273-6696 ; University Hospital of Split, Split, Croatia
Vedran Carević orcid id orcid.org/0000-0002-0009-5009 ; University Hospital of Split, Split, Croatia
Tea Domjanović Škopinić orcid id orcid.org/0000-0002-4989-6974 ; University Hospital of Split, Split, Croatia
Ivona Mustapić orcid id orcid.org/0000-0002-1534-3642 ; University Hospital of Split, Split, Croatia
Darija Baković Kramarić orcid id orcid.org/0000-0001-6751-5242 ; University Hospital of Split, Split, Croatia


Full text: english pdf 253 Kb

page 111-112

downloads: 133

cite

Download JATS file


Abstract

Keywords

mitral annulus disjunction; Barlow’s syndrome; mitral valve prolapse; echocardiography

Hrčak ID:

300895

URI

https://hrcak.srce.hr/300895

Publication date:

27.4.2023.

Visits: 426 *



Introduction: Mitral annulus disjunction (MAD) is an abnormal insertion of the mitral annulus flexion line into the atrial wall, often described in association with Barlow’s syndrome, a myxomatous mitral valve degeneration, causing mitral valve prolapse (MVP). It is the most common cause of primary mitral regurgitation (MR) (1,2). Both have been linked to increased arrhythmic risk and sudden cardiac death (3).

Case report: 28-year-old patient with no previous medical history presented with palpitations, occasional shortness of breath and near loss of consciousness, especially during sport activities. Auscultatory, heart sounds were rhythmic with no murmurs except mid-systolic click. All blood tests were completely normal. Resting 12-lead electrocardiogram revealed sinus rhythm without T wave inversion or ventricular ectopic beats. Transthoracic echocardiography and transesophageal echocardiography verified borderline size and normal function of left ventricle, clear signs of MAD (Figure 1) and myxomatous changes of both anterior and posterior mitral valve leaflets with mild mitral regurgitation (Figure 2). Cardiac magnetic resonance imaging (CMR) confirmed MAD (Figure 3). The 24-hours Holter ECG monitoring did not confirm the presence of malignant ventricular arrhythmia. However, we decided to implant loop recorder for prolong rhythm monitoring of patient with MAD and Barlow’s disease.

FIGURE 1 Transthoracic echocardiography. Four chamber view: green arrows are pointing at mitral annulus disjunction.
CC202218_5-6_111-2-f1
FIGURE 2 Transesophageal echocardiography; left image 2D echocardiography and right image 3D echocardiography. Myxomatous mitral valve changes with mitral valve prolapse.
CC202218_5-6_111-2-f2
FIGURE 3 Cardiac magnetic resonance imaging: white arrow is pointing at mitral annulus disjunction.
CC202218_5-6_111-2-f3

Conclusion: Echocardiography is unavoidable method in diagnosis of mitral annulus disjunction. MAD is common finding in myxomatous valve disease and can cause symptoms of heart failure and potential life threatening ventricular arrhythmias highlighting the importance of its recognizing and treating.

LITERATURE

1 

Souza AC, Carvalho MVSF, Sales MA, Bezerra SL, Torreão JA, Macêdo CT. Mitral Annulus Disjunction: Diagnostic Modalities, Clinical Implications, and Prognostic Progression. Arq Bras Cardiol: Imagem cardiovasc. 2022;35(3):eabc300. https://doi.org/10.47593/2675-312X/20223503eabc300 https://doi.org/10.47593/2675-312X/20223503eabc300

2 

Anyanwu AC, Adams DH. Etiologic classification of degenerative mitral valve disease: Barlow’s disease and fibroelastic deficiency. Semin Thorac Cardiovasc Surg. 2007 Summer;19(2):90–6. https://doi.org/10.1053/j.semtcvs.2007.04.002 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/17870001

3 

Dejgaard LA, Skjølsvik ET, Lie ØH, Ribe M, Stokke MK, Hegbom F, et al. The Mitral Annulus Disjunction Arrhythmic Syndrome. J Am Coll Cardiol. 2018 October 2;72(14):1600–9. https://doi.org/10.1016/j.jacc.2018.07.070 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/30261961


This display is generated from NISO JATS XML with jats-html.xsl. The XSLT engine is libxslt.