Skip to the main content

Original scientific paper

Microleakage of Different Root Canal Obturation Techniques

Nevena Devčić
Ivana Miletić
Sonja Pezelj-Ribarić
Sanja Šegović


Full text: croatian pdf 76 Kb

page 77-80

downloads: 731

cite

Full text: english pdf 68 Kb

page 81-84

downloads: 1.835

cite


Abstract

Leakage examination was performed using fluid transport system measuring movement of an air bubble. Tested techniques were cold lateral condensation technique, Touch`n Heat and Thermafil technique. Root canals were obturated with gutta-percha in combination with AH Plus and RoekoSeal sealers. After storing in saline solution, microleakage was measured in intervals of one month, six months and one year. The minimum microleakage values were obtained in all intervals in canals obturated using cold lateral condensation technique, while maximum values were obtained in Thermafil technique (p< 0.05). Significantly more leakage was found for all tested techniques in the interval of 12 months after obturation (p< 0.05). There was no difference between obturation quality between RoekoSeal and AH Plus, no matter what obturation technique was used.

Keywords

fluid transport system; cold lateral condensation technique; Touch`n Heat; Thermafil