Skip to the main content

Original scientific paper

Direct Torque Control of Induction Motor with Stator Flux Correction

Dubravko Krušelj
Mario Bilić
Boris Furčić
Vladimir Siladi
Miroslav Vučetić


Full text: english pdf 1.694 Kb

page 41-46

downloads: 974

cite


Abstract

Direct torque control (DTC) method with correction of stator flux vector is presented in the paper. The correction is made by means of appropriate component of stator current vector. Thus, controlled quantities (electromagnetic torque and stator flux) are estimated only from stator parameters and measured stator quantities, and there is no need to use rotor parameters, which are dependent on the operating condition, and rotor quantities, which cannot be measured. With the proposed method stable operation in whole speed range, robust start-up with slow change of the torque and fast torque response are achieved. Simulations and experimental tests verify the validity of the method.

Keywords

induction motors; estimation techniques; vector control

Hrčak ID:

6756

URI

https://hrcak.srce.hr/6756

Publication date:

3.12.2003.

Article data in other languages: croatian

Visits: 2.584 *