Skip to the main content

Preliminary communication

Diagnosis of industrial gearboxes condition by vibration and time-frequency, scale-frequency, frequency-frequency analysis

P. Czech ; Silesian University of Technology, Faculty of Transport, Department of Automotive Vehicle Construction, Katowice, Poland


Full text: english pdf 893 Kb

page 521-524

downloads: 857

cite


Abstract

In the article methods of vibroacoustic diagnostics of high-power toothed gears are described. It is shown below, that properly registered and processed acoustic signal or vibration signal may serve as an explicitly interpreted source of diagnostic symptoms. The presented analysis were based on vibration signals registered during the work of the gear of a rolling stand working in Katowice Steel Plant (presently one of the branches of Mittal Steel Poland JSC).

Keywords

mechanical engineering; gear; acoustic signal; diagnosis

Hrčak ID:

82921

URI

https://hrcak.srce.hr/82921

Publication date:

1.10.2012.

Article data in other languages: croatian

Visits: 1.833 *