Metallurgy, Vol. 52 No. 3, 2013.
Original scientific paper
Loss of aluminium during the process of Ti-Al-V alloy smelting in a vacuum induction melting (VIM) furnace
L. Blacha
; Silesian University of Technology, Department of Metallurgy, Katowice, Poland
G. Siwiec
; Silesian University of Technology, Department of Metallurgy, Katowice, Poland
B. Oleksiak
; Silesian University of Technology, Department of Metallurgy, Katowice, Poland
Abstract
In the present paper, results of the study on changes in basic Ti-6Al-4V alloy component contents during smelting in the vacuum induction melting (VIM) furnace are presented. The experiments were performed at 5 – 1 000 Pa and 1 973–2 023 K. Assuming that the observed loss of aluminium from the alloy during smelting is the effect of evaporation, an additional thermodynamic analysis was performed aimed at determining evaporation coefficients.
Keywords
Ti-Al-V alloys; VIM technology; evaporation of Al; coefficient of evaporation
Hrčak ID:
95667
URI
Publication date:
1.7.2013.
Visits: 2.165 *