Influence of heat treatment on the silver-palladium alloy microstructure

Jesenka Živko-Babić ; School of Dental Medicine, University of Zagreb, Zagreb, Croatia


Full text: croatian pdf 10.564 Kb

page 109-119

downloads: 891

cite


Abstract

Cast dental alloys, even those made of precious metals, are not homogeneous. In order to ensure a high-quality cast, it was necessary to determine optimal casting temperature and additional heat treatment to allow for homogenization of the cast in the microarea of the dendritic structure to occur which, in turn, implies chemical inertia of the metal construction to the organic medium of the mouth. A number of melting, homogenizing and aging tests showed the optimal regimen for bringing an Ag-Pd alloy to the level of hardness of the tooth enamel (about 330 HV 0.1) to consist of a technological treatment involving the following procedures: casting at 1100— 1150°C, homogenization at 850°C, quenching in water and 20-min precipitation at 350°C.

Keywords

Silver-palladium alloy; casting; homogenization

Hrčak ID:

101234

URI

https://hrcak.srce.hr/101234

Publication date:

15.6.1989.

Article data in other languages: croatian

Visits: 1.773 *