Skip to the main content

Preliminary communication

https://doi.org/10.14256/JCE.867.2013

Seismic behaviour of buildings founded on thermal insulation layer

Vojko Kilar ; Sveučilište u Ljubljani, Arhitektonski fakultet
David Koren ; Sveučilište u Ljubljani, Arhitektonski fakultet
Martina Zbašnik-Senegačnik ; Sveučilište u Ljubljani, Arhitektonski fakultet


Full text: english pdf 582 Kb

page 423-433

downloads: 555

cite

Full text: croatian pdf 595 Kb

page 423-433

downloads: 2.910

cite


Abstract

Thermal insulation under the building foundation plate or under the strip foundations prevents the thermal bridge on the contact between the building and supporting terrain and reduces the energy consumption in modern passive and low energy houses. In the paper the seismic behaviour of buildings with different heights, floor plan dimensions, on different soil conditions and on different thermal insulation layers have been analysed. The results of simplified seismic analyses have shown, that the potentially negative influences of inserting the insulation under the foundation plate could be expected only for buildings with more than two or three storeys.

Keywords

passive house; earthquake; seismic behaviour; foundations on thermal insulation

Hrčak ID:

103438

URI

https://hrcak.srce.hr/103438

Publication date:

4.6.2013.

Article data in other languages: croatian

Visits: 4.197 *