Percutaneous closure of paravalvular leak — case report on first procedure in Croatia

Robert Bernat orcid id orcid.org/0000-0001-8722-9497 ; Magdalena -— Clinic for cardiovascular diseases, Medical Faculty Osijek Krapinske Toplice, Croatia
Aleksandar Trbović ; Magdalena -— Clinic for cardiovascular diseases, Medical Faculty Osijek Krapinske Toplice, Croatia
Mladen Novkoski ; Magdalena -— Clinic for cardiovascular diseases, Medical Faculty Osijek Krapinske Toplice, Croatia
Zvonimir Ante Korda ; Magdalena -— Clinic for cardiovascular diseases, Medical Faculty Osijek Krapinske Toplice, Croatia


Full text: croatian pdf 225 Kb

page 407-410

downloads: 472

cite

Full text: english pdf 225 Kb

page 407-410

downloads: 183

cite


Abstract

Clinically significant paravalvular leak (PVL) after prosthetic valve implantation is a rare, but potentially serious complication. Repeat surgery is associated with significant risks and may fail, because the original cause of leak is not always amenable to correction. Percutaneous PVL closure has been introduced as an important alternative with documented good immediate and late results.
We present a case of PVL closure in a young patient using the Amplatzer Vascular plug III device, guided by periprocedural transesophageal echocardiography. Immediate success and mid-term result could be documented. In view of the significant number of prosthetic valve implantations in Croatia, an increase in the need for this type of intervention can be expected each year.

Keywords

prosthetic valve replacement; paravalvular leak; percutaneous closure