Skip to the main content

Original scientific paper

Investigation of Dynamic Loading Fatigue of PMMA Resin Provisional Crowns

Amir Ćatić
Adnan Ćatović
Željko Alar


Full text: croatian pdf 71 Kb

page 433-438

downloads: 570

cite

Full text: english pdf 60 Kb

page 439-442

downloads: 1.186

cite


Abstract

A temporary crown or bridge is the best protection of a prepared tooth from pain, saliva contamination and caries propagation. It must have all the properties and qualities of a permanent restoration in order to properly function in the oral cavity.
The aim of the investigation was to determine the influence of two types of cervical preparation of the abutment, as well as the influence of cyclic thermal changes (5°C-55°C), on the dynamic strength of temporary crowns made of poly(methilmethacrylate) resin. The fatigue tests were performed in an Amsler's high frequency pulzator under cyclic dynamic loading in the range from 400N to 1000N.
The results of the investigation showed negative reciprocal relationship between the values of the dynamic load and the number of cycles endured without the fracture of the sample (r=-0.98). The thermocycled samples demonstrated significantly lower fracture resistance than the nonthermocycled samples (p>0.05).

Keywords

dynamic loading; provisional crowns

Hrčak ID:

11423

URI

https://hrcak.srce.hr/11423

Publication date:

15.12.2001.

Article data in other languages: croatian

Visits: 2.696 *