Skip to the main content

Other

https://doi.org/10.15836/ccar.2014.44

“Double fire” — a rare and commonly unrecognized arrhythmia.

Zoran Bakotić ; Zadar General Hospital, Zadar, Croatia
Ante Anić ; Zadar General Hospital, Zadar, Croatia
Marin Bištirlić ; Zadar General Hospital, Zadar, Croatia
Albino Jović ; Zadar General Hospital, Zadar, Croatia


Full text: croatian pdf 404 Kb

page 44-47

downloads: 238

cite

Full text: english pdf 404 Kb

page 44-47

downloads: 303

cite


Abstract

Dual atrioventricular node (AV) pathway physiology or the presence of so-called slow conduction pathway is according to various studies demonstrable in up to 35% of normal people during electrophysiology study (EPS). In only a small number of them, it has a clinical significance.
We present a case of a patient with a very rare electrophysiological manifestation of active slow pathway, double ventricular response to one atrial complex. The problem was successfully treated with radiofrequency ablation.
This form of conduction via AV node is probably much more common than it was previously described in the literature, but unfortunately it is rarely recognized and is generally refractory to medical therapy.

Keywords

dual atrioventricular node physiology; “double fire” phenomenon; radiofrequency ablation

Hrčak ID:

141152

URI

https://hrcak.srce.hr/141152

Publication date:

17.2.2014.

Article data in other languages: croatian

Visits: 1.382 *