Skip to the main content

Original scientific paper

https://doi.org/10.17559/TV-20150822145550

Experimental in-vitro bone cements disintegration with ultrasonic pulsating water jet for revision arthroplasty

Sergej Hloch orcid id orcid.org/0000-0003-4066-0620 ; Institute of Geonics of the CAS, v. v. i. Studentská 1768, 708 00 Ostrava-Poruba, Czech Republic / Faculty of Manufacturing Technologies of Technical University of Košice with a seat in Prešov, Bayerova 1, 080 01 Prešov, Slovak Republic
Josef Foldyna orcid id orcid.org/0000-0003-4288-445X ; Institute of Geonics of the CAS, v. v. i. Studentská 1768, 708 00 Ostrava-Poruba, Czech Republic
Frank Pude ; Inspire AG (ETH Zurich), Zurich, Switzerland
Ján Kľoc ; Department of Orthopaedics, J. A. Reiman Faculty Hospital with Policlinics in Prešov, Slovak Republic
Michal Zeleňák ; Institute of Geonics of the CAS, v. v. i. Studentská 1768, 708 00 Ostrava-Poruba, Czech Republic
Pavol Hvizdoš orcid id orcid.org/0000-0002-9536-4514 ; Slovak Academy of Sciences, Institute of Material Research, Watsonova 47, 040 01 Košice, Slovak Republic
Peter Monka orcid id orcid.org/0000-0002-0963-5235 ; Faculty of Manufacturing Technologies of Technical University of Košice with a seat in Prešov, Bayerova 1, 080 01 Prešov, Slovak Republic
Igor Smolko ; Department of Orthopaedics, J. A. Reiman Faculty Hospital with Policlinics in Prešov, Slovak Republic
Jiří Ščučka ; Institute of Geonics of the CAS, v. v. i. Studentská 1768, 708 00 Ostrava-Poruba, Czech Republic
Dražan Kozak orcid id orcid.org/0000-0001-5245-4686 ; Mechanical Engineering Faculty in Slavonski Brod, J. J. Strossmayer University of Osijek, Trg Ivane Brlić-Mažuranić 2, HR-35000 Slavonski Brod, Croatia
Aleksandar Sedmak ; Innovation Centre of Faculty of Mechanical Engineering, University of Belgrade, Kraljice Marije 16, 11141 Belgrade, Serbia
Emília Mihalčinová ; Department of Orthopaedics, J. A. Reiman Faculty Hospital with Policlinics in Prešov, Slovak Republic


Full text: croatian pdf 1.995 Kb

page 1609-1615

downloads: 424

cite

Full text: english pdf 1.995 Kb

page 1609-1615

downloads: 815

cite


Abstract

The paper deals with the study of using the selective property of ultrasonic pulsating water jet for the disintegration of the interface created by bone cement between cemented femoral stem and trabecular bone tissue as a potential technique for revision arthroplasty. Six types of commercial bone cements based on Polymethyl Methacrylate were used for investigation. The cements were mixed using the DePuy - SmartMix® CTS / vacuum mixing bowl. Mechanical properties of hardened bone cements were determined by nanoindentation. The bone cement samples were disintegrated using the pulsating water jet technology. The water pressure varied between 8÷20 MPa. A circular nozzle with an orifice diameter of 0,7 mm was used for water jetting. The stand-off distance from the target material was 2 mm and the traverse speed 1 mm/s. The volume of material removal and depth of created traces were measured by MicroProf FRT optical profilometer. The results positively support an assumption that pulsating water jet has a potential to be a suitable technique for the quick and safe disintegration of bone cement during revision arthroplasty.

Keywords

bone cement; revision arthroplasty; ultrasonic pulsating water jet

Hrčak ID:

149405

URI

https://hrcak.srce.hr/149405

Publication date:

14.12.2015.

Article data in other languages: croatian

Visits: 2.935 *