Skip to the main content

Original scientific paper

https://doi.org/10.7305/automatika.2016.10.1663

Application of Open-Circuit IGBT Faults Diagnostic Method in DTC-SVM Induction Motor Drive

Piotr Sobanski ; Department of Electrical Machines, Drives and Measurements, Faculty of Electrical Engineering, Wroclaw University of Science and Technology, ul. Wybrzeze Wyspianskiego 27, 50-370 Wroclaw, Poland
Teresa Orlowska-Kowalska ; Department of Electrical Machines, Drives and Measurements, Faculty of Electrical Engineering, Wroclaw University of Science and Technology, ul. Wybrzeze Wyspianskiego 27, 50-370 Wroclaw, Poland


Full text: english pdf 1.124 Kb

page 387-395

downloads: 772

cite


Abstract

In this paper a simple diagnostic method of a single IGBT open-circuit fault is presented, it is dedicated for three-phase two-level voltage-inverter-fed vector controlled induction motor drive systems. A failure diagnosis is based on a transient analysis of a reference voltage space vector in stationary coordinates, without additional sensors. The diagnostic algorithm ensures detection and localization of single IGBT failures in time shorter than one period of a stator current fundamental harmonic, without regard to a drive operation point. The presented scheme of the diagnostic system can be easily applicable in the electric drives that use voltage space vector modulation algorithms. The main achievement of the research, whose results have been presented in this paper, is an experimental validation of the analyzed IGBT faults diagnosis technique in the drive with the Direct Torque Control algorithm.

Keywords

Induction motor drive; condition monitoring; open-circuit fault; direct torque control; diagnostic technique

Hrčak ID:

179433

URI

https://hrcak.srce.hr/179433

Publication date:

25.1.2017.

Article data in other languages: croatian

Visits: 1.410 *