Skip to the main content

Original scientific paper

https://doi.org/10.17559/TV-20151022121953

Robustness of contact-less optical method, used for measuring contact wire position in changeable lighting conditions

Jacek Skibicki orcid id orcid.org/0000-0003-1373-0961 ; Gdansk University of Technology, Faculty of Electrical and Control Engineering, Department of Electrical Engineering in Transport, ul. G. Narutowicza 11/12, 80-233, Gdańsk, Poland


Full text: croatian pdf 6.034 Kb

page 1759-1768

downloads: 545

cite

Full text: english pdf 6.034 Kb

page 1759-1768

downloads: 471

cite


Abstract

The article presents verification of robustness of contactless method based on 2D image camera, which is used to measure catenary contact wire position in changeable ambient lighting conditions. Robustness in changeable lighting conditions is ensured through the combination of advanced image processing for background information removal and the algorithm of error correction. This algorithm detects incorrect images and substitutes information from these images with proper measurement data obtained from correct images which precede and follow the incorrect one. The paper presents and discusses the processing algorithms used, as well as shows examples of measurement results obtained on a full scale laboratory stand.

Keywords

contact line; diagnostic systems; electric traction; measurement systems

Hrčak ID:

190172

URI

https://hrcak.srce.hr/190172

Publication date:

3.12.2017.

Article data in other languages: croatian

Visits: 2.305 *