Medicinski vjesnik, Vol. 30 No. (1-2), 1998.
Professional paper
The analysis of ultrasound vs. CT guided punctional biopsies
Branko Dmitrović
Otmar Rubin
Mladen Marcikić
Gordan Šarić
Milanka Mrčela
Tonći Mišević
Damir Dumić
Valerija Blažičević
Abstract
We have analyzed VS. CT guided punctional biopsy cases performed at the Osijek Clinical Hospital in the last two year (1996 - 1997). There were 44 patients, 32 male and 12 female. The most targeted organs were liver (62.5%), pancreas (14.6%) and spleen (6.2 5%). The biopsies were performed with common biopsy needles (True Cut, Vacu Cut, Otto ) or with automatic devices (Auto vac, Magnum). The material was classified according to : the gender and age of patients, the type and thickness of biopsy needles, the quality of tissue sample, and the way of the punctional needle guidance. The statistical data analysis does not show significant difference in a tissue sample quality regardless of either the punctional needle thickness, or the guidance with the ultrasound or CT.
Keywords
punctures; biopsy; ultrasound; CT
Hrčak ID:
192233
URI
Publication date:
1.12.1998.
Visits: 2.339 *