90mTc-Pahida - new pharmaceutical for dynamic renal scintigraphy

Boris Ajdinović
Blagorodna Zmbova
Marija Rastovac
Miodrag Odavić
Svetislav Ranđelović


Full text: croatian pdf 1.456 Kb

page 15-18

downloads: 613

cite

Full text: english pdf 1.456 Kb

page 15-18

downloads: 110

cite


Abstract

The organ distribution data for 90mTc-Pahida on animals and results of dynamic renal scintigraphy using this radiopharmaceutical in patients with normal renal function are presented. The results of dynamic renal scintigraphy with 90mTc-Pahida and results of dynamic renal scintigraphy with 131I-hippuran are compared. Organ distribution data show that 8% of administered dose is in kidneys 2 min. after administration and 2.2% 60 min. after administration. After one hour 72% of the injected dose is eliminated in urine. Investigations in patients show that PAHIDA has slower urinary elimination than hippuran, but better performances for visualisation of kidneys.

Keywords

90mTc-Pahida; dynamic scintigraphy of the kidney radiopharmaceutical