Skip to the main content

Original scientific paper

https://doi.org/10.17559/TV-20160501130126

Fault Diagnostic System for Centrifugal Milk Separator’s Rotor Bearings with Vibration Isolators

Andrius Trumpa ; Vilnius Gediminas Technical University, Department of Mechanical and Material Engineering, J. Basanavičiaus 28, 03224 Vilnius, Lithuania
Vladas Vekteris ; Vilnius Gediminas Technical University, Department of Mechanical and Material Engineering, J. Basanavičiaus 28, 03224 Vilnius, Lithuania
Vadim Mokšin orcid id orcid.org/0000-0002-7786-7150 ; Vilnius Gediminas Technical University, Department of Mechanical and Material Engineering, J. Basanavičiaus 28, 03224 Vilnius, Lithuania
Artūras Kilikevičius orcid id orcid.org/0000-0002-4039-7300 ; Vilnius Gediminas Technical University, Department of Mechanical and Material Engineering, J. Basanavičiaus 28, 03224 Vilnius, Lithuania


Full text: english pdf 2.222 Kb

page 986-990

downloads: 821

cite


Abstract

The paper deals with the fault diagnostic system of centrifugal milk separator’s rotor bearings with vibration dampers. The diagnostic system consists of a number of accelerometers attached to the outer ring of the upper bearing of the rotor and the separator’s housing. Such a system allows measuring bearing outer ring vibrations directly and indirectly (through the housing) and at the same time it allows to evaluate the impact of bearing vibration dampers. Direct and indirect bearing vibration measurement results and the differences between them are presented in the paper as well as the relationship between the vibration acceleration and excitation force spectra.

Keywords

centrifugal milk separator; fault diagnostics; rolling element bearings; vibration damper

Hrčak ID:

204442

URI

https://hrcak.srce.hr/204442

Publication date:

20.8.2018.

Visits: 1.798 *