Skip to the main content

Preliminary communication

https://doi.org/10.14256/JCE.2524.2018

Seismic load tests on exterior beam-column connections of existing RC structures

Turgay Cosgun
Cumhur Cosgun
Abdulrauf Kanishka
Atakan Mangir
Baris Sayin
Ahmet Murat Türk


Full text: english pdf 1.300 Kb

page 1129-1141

downloads: 374

cite

Full text: croatian pdf 1.320 Kb

page 1129-1141

downloads: 1.000

cite


Abstract

Suggestions for improving seismic performance of beam-column connections of the existing RC structures are presented in this paper. The use of low-strength concrete with plain bars without stirrups in joints is analysed, and behaviour of joints in the aforementioned conditions under cyclic load is investigated. Five specimens with different reinforcement configurations were produced and tested in the experimental process. Based on results, it was concluded that critical parameters for the performance of existing structures are: stirrup arrangement in joints, and the use of at least 90-degree hooks in longitudinal reinforcement of beams.

Keywords

RC beam-column joint; low-strength concrete; cyclic load; experimental study

Hrčak ID:

232068

URI

https://hrcak.srce.hr/232068

Publication date:

13.1.2020.

Article data in other languages: croatian

Visits: 2.004 *