Skip to the main content

Meeting abstract

https://doi.org/10.15836/ccar2023.260

The Transcatheter Mitral Valve Replacement program at the University Hospital Centre Zagreb – a case series

Vlatka Rešković Lukšić orcid id orcid.org/0000-0002-4721-3236 ; University Hospital Centre Zagreb, Zagreb, Croatia
Sandra Jakšić Jurinjak orcid id orcid.org/0000-0002-7349-6137 ; University Hospital Centre Zagreb, Zagreb, Croatia
Joško Bulum orcid id orcid.org/0000-0002-1482-6503 ; University Hospital Centre Zagreb, Zagreb, Croatia
Ivica Šafradin orcid id orcid.org/0000-0003-4519-5940 ; University Hospital Centre Zagreb, Zagreb, Croatia
Kristina Krželj orcid id orcid.org/0000-0003-2269-3138 ; University Hospital Centre Zagreb, Zagreb, Croatia
Maja Čikeš orcid id orcid.org/0000-0002-4772-5549 ; University Hospital Centre Zagreb, Zagreb, Croatia
Ivo Planinc orcid id orcid.org/0000-0003-0561-6704 ; University Hospital Centre Zagreb, Zagreb, Croatia
Karlo Gjuras orcid id orcid.org/0009-0006-9137-3014 ; University of Zagreb, School of Medicine, Zagreb, Croatia
Davor Miličić orcid id orcid.org/0000-0001-9101-1570 ; University Hospital Centre Zagreb, Zagreb, Croatia
Hrvoje Gašparović orcid id orcid.org/0000-0002-2492-3702 ; University Hospital Centre Zagreb, Zagreb, Croatia
Jadranka Šeparović Hanževački orcid id orcid.org/0000-0002-3437-6407 ; University Hospital Centre Zagreb, Zagreb, Croatia


Full text: english pdf 811 Kb

page 260-261

downloads: 173

cite

Download JATS file


Abstract

Keywords

mitral regurgitation; transcatheter mitral valve replacement; echocardiography

Hrčak ID:

307804

URI

https://hrcak.srce.hr/307804

Publication date:

6.9.2023.

Visits: 471 *



Background: Mitral regurgitation (MR) is a common valvular heart disease (1). Without treatment prognosis is poor, especially if left ventricular (LV) function is reduced (2). In high-risk patients who are not eligible candidates for surgery or transcatheter edge-to-edge repair (TEER), transcatheter mitral valve replacement (TMVR) is a viable option (2,3). All-cause mortality is highest 3-months after valve implantation, while improvement in symptoms and reduction of MR severity are sustained after 2-years of follow-up (2).

Case series: From April to July 2023, four high-risk patients underwent TMVR with TendyneTM valve (Abbott Vascular, CA, USA) implantation in UHC Zagreb.

Case 1 is a 75-year-old female with degenerative MR and preserved LV function – due to fragility and comorbidities the patient was not a candidate for mitral valve (MV) surgery, while due to calcification and MV leaflet morphology TEER was denied. After successful TMVR, mean pressure gradient was 4-5mmHg, no residual MR.

Case 2 is a 72-year-old-male with ischemic cardiomyopathy (CMP) who underwent CABG 20 years ago. Due to heart failure, atrial fibrillation with bradycardia and LBBB, CRT was implanted. Because of severe MR due to prolapse P1/P2 and chordal rupture, the patient was a candidate for TMVR – postprocedural mean PG was 5-6mmHg, no residual MR.

Case 3 is a 76-year-old female with toxic CMP after chemotherapy for breast cancer and functional MR. Due to deep indentations on the posterior leaflet, TEER was denied, so TMVR was performed – post implantation mean PG was 3mmHg, no residual MR.

Case 4 is a 65-year-old male to whom surgical AVR was performed in 2017 due to endocarditis. In 8/2022 due to prosthesis degeneration and HF, he underwent valve-in-valve TAVI. Re-do surgery at that time was denied due to comorbidities (end-stage renal disease- on hemodialysis, COPD, toxic liver lesion), even though severe degenerative MR was also known. Clinical improvement after TAVI was significant, but he was hospitalized due to HF, and MR did not improve, so he was referred for TMVR. After TMVR, mean PG was 6-7mmHg with trace of paravalvular MR (Figure 1).

FIGURE 1 Case 4: Three-dimensional transesophageal echocardiography recorded during transcatheter mitral valve replacement, showing a good position of Tendyne valve after deployment.
CC202318_9-10_260-1-f1

Conclusion: All patients had undergone the TMVR procedure without complications, with good short-term outcomes. Although there are still not enough studies, the existing evidence indicate that TMVR with TendyneTM valve (Abbott Vascular, CA, USA) is a good option for high-risk patients who are not candidates for surgery nor TEER, with high success implantation rate and good short-term outcomes. Concerns about valve durability and long-term outcomes are yet to be resolved.

LITERATURE

1 

Patel JS, Kapadia SR. The Tendyne transcatheter mitral valve replacement system for the treatment of mitral regurgitation. Future Cardiol. 2019 May;15(3):139–43. https://doi.org/10.2217/fca-2018-0090 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/30920301

2 

Muller DWM, Sorajja P, Duncan A, Bethea B, Dahle G, Grayburn P, et al. 2-Year Outcomes of Transcatheter Mitral Valve Replacement in Patients With Severe Symptomatic Mitral Regurgitation. J Am Coll Cardiol. 2021 November 9;78(19):1847–59. https://doi.org/10.1016/j.jacc.2021.08.060 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/34736561

3 

Niikura H, Gössl M, Sorajja P. Transcatheter Mitral Valve Replacement with Tendyne. Interv Cardiol Clin. 2019 July;8(3):295–300. https://doi.org/10.1016/j.iccl.2019.02.003 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/31078185


This display is generated from NISO JATS XML with jats-html.xsl. The XSLT engine is libxslt.