Skip to the main content

Original scientific paper

Periodontal Evaluation of Patients with Ceramic Fused-to-Metal and Acrylate Fused-to-Metal Crowns over a Period of 1 to 5 Years

Lejla Dautović-Kazazić ; School of Dental Medicine University of Sarajevo, Bosna and Hercegovina
Sead Redžepagić ; School of Dental Medicine University of Sarajevo, Bosna and Hercegovina
Muhamed Ajanović ; School of Dental Medicine University of Sarajevo, Bosna and Hercegovina
Alma Gavranović ; School of Dental Medicine University of Sarajevo, Bosna and Hercegovina
Sanela Strujić ; School of Dental Medicine University of Sarajevo, Bosna and Hercegovina


Full text: croatian pdf 275 Kb

page 34-46

downloads: 718

cite

Full text: english pdf 275 Kb

page 34-46

downloads: 1.174

cite


Abstract

Purpose:The purpose of this study was to examine if there is any difference between observed teeth (abutment teeth) and control teeth (homologous) in patients with acrylate fused-to-metal (AFM) crowns and those with ceramic fused-to-metal (CFM) crowns, and if there is any difference between AFM and CFM crowns in terms of plaque index, gingival index, retention index, CPITN, marginal gingiva retraction and bone resorption. The next objective was to examine if the length of use of AFM and CFM crowns bears any impact on these indices. Material and methods: The study included 80 patients of both sexes aged 20 to 65 with fixed prosthetics (single crowns). All the research parameters were obtained from clinical examinations and radiographic analyses. Results showed that in the group of patients with AFM crowns there was a statistically significant difference between observed and control teeth in terms of gingival index, CPITN, retention index and marginal gingiva retraction, whereas there was no statistically significant difference for other indices observed. Results also showed that in patients with CFM crowns there was a statistically significant difference between observed and control teeth in terms of plaque index, gingival index,
CPITN, retention index and marginal gingiva retraction, whereas there was no statistically significant difference for bone resorption. A statistically significant difference was found between AFM and CFM only in terms of plaque index. Conclusion: The length of use of the prosthetic appliance (under five years) in the group with AFM crowns did influence the plaque index, the depth of periodontal sulcus and the marginal gingiva retraction. The length of use of fixed prosthetic appliances (under five years) in the group with CFM crowns did not influence the indices observed.

Keywords

Metal Ceramic Alloys; Composite Resins; Dental Plaque Index, Alveolar Bone Loss; Crown

Hrčak ID:

48931

URI

https://hrcak.srce.hr/48931

Publication date:

15.3.2010.

Article data in other languages: croatian

Visits: 2.981 *