Skip to the main content

Original scientific paper

Analysis of Factors that Influence Micro-Resistance Measuring

Eraldo BANOVAC ; Mechanical Engineering Faculty Josip Juraj Strossmayer University of Osijek,Slavonski Brod, Croatia
Dražan KOZAK


Full text: english pdf 1.596 Kb

page 261-270

downloads: 747

cite


Abstract

The micro-resistance measuring principle with specific forms of current
distribution in the plated through-hole of printed circuit board (PCB) is analyzed in this paper. Special attention is paid to the following factors that influence the micro-resistance measuring: the hole diameter, the type of the measuring probe and the PCB thickness, and their two and three-factor interactions. The experiment with three repetition of measurement is carried out for which the dispersion analysis includes: the calculated values of the sum of the square of deviation, the mean of the square of deviation and a comparison between the calculated factors and the relevant factor given for five percent α-risk. The results of the dispersion analysis clearly indicate that the strongest factor that influences the micro-resistance measures is the PCB thickness. The overall
conclusion is that the effect of each considered factor to the micro-resistance measures is expressive, but the effect of their mutual interactions is not significant in the measuring practice.

Keywords

Dispersion analysis; Micro-resistance measuring method; Plated-through hole; Thickness measuring

Hrčak ID:

64343

URI

https://hrcak.srce.hr/64343

Publication date:

30.6.2010.

Article data in other languages: croatian

Visits: 2.063 *