Original scientific paper
Analysis of Factors that Influence Micro-Resistance Measuring
Eraldo BANOVAC
; Mechanical Engineering Faculty Josip Juraj Strossmayer University of Osijek,Slavonski Brod, Croatia
Dražan KOZAK
Abstract
The micro-resistance measuring principle with specific forms of current
distribution in the plated through-hole of printed circuit board (PCB) is analyzed in this paper. Special attention is paid to the following factors that influence the micro-resistance measuring: the hole diameter, the type of the measuring probe and the PCB thickness, and their two and three-factor interactions. The experiment with three repetition of measurement is carried out for which the dispersion analysis includes: the calculated values of the sum of the square of deviation, the mean of the square of deviation and a comparison between the calculated factors and the relevant factor given for five percent α-risk. The results of the dispersion analysis clearly indicate that the strongest factor that influences the micro-resistance measures is the PCB thickness. The overall
conclusion is that the effect of each considered factor to the micro-resistance measures is expressive, but the effect of their mutual interactions is not significant in the measuring practice.
Keywords
Dispersion analysis; Micro-resistance measuring method; Plated-through hole; Thickness measuring
Hrčak ID:
64343
URI
Publication date:
30.6.2010.
Visits: 2.063 *