Skip to the main content

Review article

https://doi.org/10.11613/BM.2025.010502

Is the stability of ACTH in whole blood a genuine concern during the preanalytical phase? A systematic review

Ahmad Dib ; Department of Clinical Biochemistry, University Hospital of Dijon Burgundy, Dijon, France
Damien Leleu ; Department of Clinical Biochemistry, University Hospital of Dijon Burgundy, Dijon, France; Center for Translational and Molecular Medicine, Unit 1231, Université Bourgogne Europe, Dijon, France
Stéphanie Lemaire ; Department of Clinical Biochemistry, University Hospital of Dijon Burgundy, Dijon, France
Laurence Duvillard ; Department of Clinical Biochemistry, University Hospital of Dijon Burgundy, Dijon, France
Louise Ménégaut ; Department of Clinical Biochemistry, University Hospital of Dijon Burgundy, Dijon, France
Damien Denimal ; Department of Clinical Biochemistry, University Hospital of Dijon Burgundy, Dijon, France; Center for Translational and Molecular Medicine, Unit 1231, Université Bourgogne Europe, Dijon, France *

* Corresponding author.


Full text: english pdf 241 Kb

page 27-37

downloads: 73

cite

Download JATS file


Abstract

Adrenocorticotropic hormone (ACTH) has historically been considered an unstable hormone after venous sampling, necessitating stringent conditions for the transport of blood samples to the laboratory to ensure accurate measurement. However, recent investigations suggest that ACTH may be more stable than previously assumed, raising the possibility of more flexible handling conditions. This prompted us to conduct a systematic review using the MEDLINE database to ascertain the stability of ACTH in blood samples. We included 9 studies in our final analysis from 405 reports. Our findings reveal that all studies reported a mean percentage difference (PD%) in ACTH concentrations relative to baseline below the 10% threshold when uncentrifuged tubes were stored under refrigerated conditions for 2, 4, 6, and 8 hours. In contrast, the mean PD% exceed the 10% threshold in 5 out of 7 studies investigating a storage duration of 24 hours under refrigerated conditions. Nearly all studies reported a mean PD% in ACTH concentrations relative to baseline below 10% when uncentrifuged tubes were stored at room temperature for 2, 4, and 6 hours. However, for storage durations of 8, 12, and 24 hours at room temperature, most studies observed a mean PD% exceeding 10%. In summary, our findings suggest that ACTH remains stable in uncentrifuged tubes containing EDTA for 6 h at room temperature and at least 8 h under refrigerated conditions. Our findings can assist clinical laboratories in reviewing their acceptance criteria for sample transport regarding time and temperature.

Keywords

ACTH; biochemistry; endocrinology; extra-analytical phase

Hrčak ID:

328186

URI

https://hrcak.srce.hr/328186

Publication date:

15.2.2025.

Visits: 539 *




Introduction

Human adrenocorticotropic hormone (ACTH) is a 39-amino acid peptide hormone produced by cells of the anterior pituitary gland. It acts as the primary stimulant of glucocorticoid synthesis and secretion by the adrenal cortex. Accurate measurement of circulating ACTH concentrations is pivotal for diagnosing disorders related to the hypothalamic-pituitary-adrenal axis, such as adrenal insufficiency and Cushing’s syndrome (1,2).

The preanalytical phase is particularly critical for ACTH analysis. In fact, it has long been suggested that ACTH may be unstable in whole blood after venous sampling, especially because of its degradation by blood cell proteases (3-5). Controlling the time and temperature of blood specimens before the centrifugation step therefore looks crucial to mitigate ACTH degradation. In fact, clinical laboratories often advocate for stringent conditions regarding the duration and temperature of transport to the laboratory of blood samples. For instance, a review of the preanalytical instructions issued by 33 university hospitals and private clinical laboratories across France revealed that 76% of them request transport under refrigerated conditions, while the remaining 24% accept transport at room temperature (RT) (personal unpublished review based on laboratory websites, conducted on March 7, 2024). The recommended maximum duration of transport of blood samples is heterogeneous, with 12% of laboratories suggesting a maximum of 30 min, 15% advising up to 2 h, 36% extending the limit to 4 h, while only 37% have acceptance criteria greater than 4 h.

In contrast to these current practices, recent published data suggest that ACTH may exhibit more stability in whole blood than previously assumed. In particular, two studies recently demonstrated that the storage of whole blood for 8 or 12 h at 4 °C did not impact plasma ACTH concentrations (6,7). In addition, Dong et al. recently found that ACTH was also stable in whole blood for 6 h at 22 °C (7). These recent findings raise questions about current practices in clinical laboratories, and this prompted us to conduct a systematic literature review to elucidate the stability of ACTH concentration in whole blood regarding storage duration and temperature. Such approach may contribute to the harmonization of preanalytical instructions across clinical laboratories (8).

Materials and methods

The protocol for this systematic review was registered in the PROSPERO database (#CRD42024540452), and is presented according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 statement (9).

Eligibility criteria

Table 1 shows the study characteristics used to decide whether a study was eligible for inclusion in the review, according to the Population, Intervention, Comparison, Outcome, Study (PICOS) search question format.

Table 1 Eligibility criteria for the selection of studies
PICOS parameterInclusion criteriaExclusion criteria
PopulationHuman blood samples from individuals of any age, gender, ethnicity, health conditions, and ACTH concentrations.
Any collection tubes with any additives.
Any analytical methods.
Non-human blood.
Biological matrices other than blood (e.g., quality control materials).
InterventionShort-term storage of whole blood (≤ 24 h) at a temperature higher than 0 °C before centrifugation.Immediate centrifugation after blood collection (i.e., studies with storage of serum or plasma).
Long-term storage (> 24 h) and/or at a negative temperature.
ComparisonCirculating ACTH concentrations at baseline (immediately centrifuged and analyzed or frozen after venipuncture).
OutcomesThe primary outcome was the difference in ACTH concentration after storage (expressed in percentage difference from baseline). Any measure of the precision of the percentage difference in ACTH concentrations was collected (e.g., standard deviation or interquartile range).Reports were excluded if the calculation of the percentage difference (PD%) in ACTH concentrations following storage was not directly available in the article.
Study designArticles published in peer-reviewed journals.
Any date of publication.
Articles not published in English, case reports, meta-analysis, reviews, expert opinions, conference reports.
ACTH - adrenocorticotropic hormone.

Information sources and search strategy

The search procedure was conducted using the PubMed/MEDLINE database. The search strategy was as follows: ((ACTH[Title/Abstract]) OR (adrenocorticotrop*[Title/Abstract])) AND ((stability[Title/Abstract]) OR (storage[Title/Abstract])). In addition, the references cited in the included studies were examined to select additional reports for screening. All reports published up to April 1, 2024, were included for further screening.

Selection and data collection process

Two authors independently screened the titles and abstracts, excluding reports and studies based on the predefined inclusion and exclusion criteria. The remaining studies were integrally read to definitively judge on their inclusion. Disagreements on the eligibility of studies were resolved through discussion and consensus between authors. Data from each report were independently collected in Excel sheets by two authors. No automation tool was used in the selection process or in data collection.

Data items (outcomes)

The primary outcome was the difference between the baseline concentration of circulating ACTH and the concentration after storage of whole blood in each condition, expressed as percentage difference (PD%). Data on the precision of the PD% in concentrations were also collected.

Study risk of bias assessment

The risk of bias in the included studies was independently evaluated by two authors using an adapted version of the quality grading tool developed by Gomez-Rioja et al. for stability studies (10). Two criteria were omitted from the original quality grading tool as they were deemed inappropriate for our study: total drawn volume and time before centrifuging. Regarding the criterion “type of centrifugation”, when the authors did not specify adherence to the tube manufacturer’s instructions, we then considered as recommended the following centrifugation conditions: ≤ 1300xg for 10 min for tubes from Becton Dickinson (Franklin Lakes, USA), 1800-2200xg for 10-15 min for Vacuette tubes from Greiner Bio-One (Kremsmünster, Austria), and 2000xg for 15 min or 2500xg for 10 min for tubes from Sarstedt (Nümbrecht, Deutschland) (11-13).

The maximum score of the adapted version of the quality grading tool was 25 points (10). Studies were classified into four quality grades: excellent if the total score exceeded 18.75 points, acceptable between 12.5 and 18.75 points, doubtful between 6.25 and 12.5 points, and unacceptable if the score was lower than 6.25 points (10). Any discrepancies in judgement between the two authors were resolved through discussion.

Effect measures

The effect measure of the primary outcome was the relative difference, expressed as PD%, between the baseline concentration of circulating ACTH and the concentration for each storage condition of uncentrifuged tubes.

Data on the precision of PD% values were expressed as standard deviation (SD). In cases where SD was not directly reported in the studies, it was calculated from other measures such as standard error mean, interquartile range and median, or error bars in graphs. Standard error mean was converted to SD using the following formula: SD = standard error mean x √n, where n represents the sample size. The approach outlined by Shi et al. was followed when SD was estimated from interquartile range, median and mean (14).

Establishing the maximum permissible difference indicative of a significant change in PD% is challenging in the case of ACTH. Such limit is typically determined from the total or acceptable change limits according to ISO 5725-6, based on analytical and within-subject biological variation (15). Unfortunately, biological variation data for ACTH were not available in either the EFLM biological variation database or the Ricos’ database (16,17). Therefore, we chose to adopt a threshold of 10% as maximum permissible difference for the mean PD%. This 10% threshold was widely used in previous studies focusing on ACTH stability (6,7,18-22).

Synthesis methods

Data were classified into two groups according to whether they were from ACTH stability studies at RT or under refrigerated conditions. For each temperature condition, they were subsequently grouped according to duration storage. Since the degradation of ACTH is time-dependent, data from the single study examining 3 h storage duration was grouped into the “2-h” subgroup (7).

Forest plots were used to visually display results of individual studies and syntheses, and they were generated using GraphPad Prism (version 9.5.0) (GraphPad Software, Boston, USA).

Results

Study selection

The PRISMA flowchart depicted inFigure 1 illustrates the selection of studies. A total of 405 reports were identified through our systematic search strategy. The vast majority (N = 382, 94%) were excluded based on the initial screening of their titles and abstracts due to their lack of adherence to our inclusion criteria.

Figure 1 PRISMA 2020 flow diagram
bm-35-1-010502-f1

Among the studies assessed for eligibility (N = 20), two were excluded as they examined the stability of ACTH concentration in plasma after immediate centrifugation following blood collection, but not in uncentrifuged tubes (23,24). Two additional studies were excluded because they specifically investigated long-term plasma storage at - 20 and - 70 °C (4,25). Some other studies were eliminated due to their focus on the stability of ACTH using internal quality control rather than freshly collected blood samples, the effects of repeated freezing and thawing of plasma, or the impact of hemolysis on ACTH stability (26-28). Lastly, two studies were excluded because PD% was not directly reported in the original articles, and only mean concentrations were provided (29,30).

Ultimately, our systematic review included 11 studies, with almost half of them (N = 6, 55%) being published within the last decade.Table 2 summarized the main characteristics of these studies. In total, 151 blood samples were analyzed. Among the 11 included studies, ten studies provided stability data under refrigerated conditions, with 9 studies indicating a storage temperature of + 4 °C and one study reporting storage in ice/water. Additionally, nine studies presented stability data at RT, with two studies not specifying the exact temperature and the remaining studies reporting temperatures ranging from 22 to 25 °C. The RT condition in the study by Bosse and Bayard was not analyzed, as the collection tubes were actually kept in a cooling container (6). However, this study was retained because it also included a storage condition at 4 °C in a refrigerator, which fully met our inclusion criteria.

Table 2 Characteristics of the selected studies
StudySample sizeCollection
tube
Time of storageTemperature of storageAnalyzer
/ method
Baseline ACTH concentrationsReference
Dong, 20243EDTA-K2*3, 6, 12
and 24 h
4, 22 °CImmulite 2000 XPi (Siemens)N.R.(7)
Bosse, 202415EDTA-K2
(Greiner)
1, 2, 4,
and 8 h
4 °C and
Crioplast at 22 °C
Liaison
(Diasorin)
17.6 ± 7.4 pg/mL(6)
Nandakumar, 202019EDTA-K2
(Becton Dickinson)
2 and 4 h4 °CElecsys Cobas 6000
(Roche)
12 samples:
< 20 pg/mL
5 samples:
20-40 pg/mL
2 samples:
> 40 pg/mL
(37)
Chakera, 201715EDTA*1, 6, 24
and 48 h
4, 20 °CModular E170
(Roche)
Median (range): 18.9 (7.7-759.6) pg/mL(22)
Wu, 201721EDTA-K2*2, 4, 8,
and 24 h
4, 22 °CModular E602 (Roche)7.2-63.3 pg/mL(18)
Christensen, 201630EDTA-K2*2, 4, 24,
and 48 h
RT,
ice/water
Cobas e601 (Roche)28 samples within the reference range (7.4-63 pg/mL).
1 sample: 6.0 pg/mL
(20)
Oddoze, 201210EDTA-K3
(Becton Dickinson)
4, 8, 12, 16 and 24 h4, 25 °CCobas e601 (Roche)N.R.(38)
Reisch, 200719EDTA
(Sarstedt)
1, 2, 4, 24 and 48 h4, 22 °CAdvantage
(Nichols)
5-774 pg/mL(21)
Ellis, 200310EDTA*0.5, 6, and 24 h4, 24 °CRadio-immunoassay
(Nichols)
7.3-45 pg/mL(19)
Diver, 19946Lithium heparin*6, 24, 48,
and 168 h
4 °C, RTAllegro HS
(Nichols)
92-94 pg/mL(32)
Lambert, 19853Heparin*1, 2 and 4 h22 °CRadio-immunoassay152-212 pg/mL(31)
*Manufacturer not provided. ACTH - adrenocorticotropic hormone. EDTA - ethylenediaminetetraacetic acid. N.R. - not reported. RT - room temperature.

Ethylenediaminetetraacetic acid (EDTA) tubes were used in 9 of the 11 selected studies, while heparinized tubes were used in two studies.

ACTH measurements were performed using automated methods from Roche (Basel, Switzerland) in 5 of the 11 selected studies, Nichols (San Juan Capistrano, USA) in two studies, Siemens (Erlangen, Deutschland) in one study, and Diasorin (Saluggia, Italy) in one study, and using manual radioimmunoassays in two studies.

Risk of bias

Table S1 (see Supplementary material) presented the assessment of risk of bias in the 11 selected studies. The quality grade was deemed acceptable for 6 of them, doubtful for 3, and unacceptable for the remaining 2 studies. The two studies deemed to be of unacceptable quality were excluded from the analysis.

ACTH stability under refrigerated conditions

Six studies provided data on the stability of ACTH concentration in uncentrifuged tubes stored under refrigerated conditions for a storage duration of 2 and 4 h, 2 studies for 6 h, 3 studies for 8 h, 2 studies for 12 h, and 7 studies for 24 h. All of these studies utilized collection tubes containing only EDTA. As shown inFigure 2, all stability studies reported a mean PD% in ACTH concentrations relative to baseline that remained below the 10% threshold when uncentrifuged tubes were stored under refrigerated conditions for 2, 4, 6, and 8 h. In contrast, in 5 out of 7 studies examining a storage duration of 24 h, the mean PD% exceeded the 10% threshold, with values ranging from - 16.0% (95% confidence interval (CI): - 22.0 to - 10.0) to + 3.3% (95% CI: - 43.9 to 50.5).

Figure 2 Forest plots depicting the stability of ACTH in uncentrifuged tubes under refrigerated conditions relative to the duration of storage prior to centrifugation. The X-axis represents the mean percentage difference (PD%) compared to the baseline concentration. Bar errors correspond to 95% confidence intervals (CI). ACTH - adrenocorticotropic hormone. NP - not provided (indicating the individual studies where the calculation of the 95% CI was not feasible with the available data).
bm-35-1-010502-f2

ACTH stability at room temperature

Four studies provided data on the stability of ACTH concentration in uncentrifuged tubes stored at RT for a storage duration of 2 and 4 h, 2 studies for 6, 8, 12 h, and 7 studies for 24 h. All of these studies utilized collection tubes containing only EDTA. As illustrated inFigure 3, nearly all studies reported a mean PD% in ACTH concentrations relative to baseline below the 10% threshold when uncentrifuged tubes were stored at RT for 2, 4, and 6 h. The only exception was the study by Wu et al., which reported a mean PD% of - 12.4% (95% CI: - 18.5 to 6.4) after 4 h of storage (18).

Figure 3 Forest plots depicting the stability of ACTH in uncentrifuged tubes at room temperature relative to the duration of storage prior to centrifugation. The X-axis represents the mean percentage deviation (PD%) compared to the baseline concentration. Bar errors correspond to 95% confidence intervals (CI). ACTH - adrenocorticotropic hormone. NP - not provided (indicating studies where the calculation of the 95% CI was not feasible with the available data, denoted by dots without error bars in the graphs).
bm-35-1-010502-f3

Nearly all studies investigating the stability of ACTH after 8, 12, and 24 h of storage at RT reported PD% greater than the 10% threshold.

Discussion

Our systematic review of the literature argues that ACTH is stable in uncentrifuged EDTA tubes for 6 h at RT and at least 8 h under refrigerated conditions. Although we found that ACTH remains stable after a 12 h storage under refrigeration, this finding is drawn from only two studies, one of which did not provide a confidence interval for the PD%, while the other reported a wide confidence interval for the mean PD%. These limitations make it difficult to draw definitive conclusions regarding ACTH stability under this storage condition, and further stability studies are needed to conclude on the ACTH stability in whole blood for storage durations greater than 8 h under refrigerated conditions (33).

Our findings bring evidence that ACTH is less prone to degradation in whole blood than previously assumed. In 2002, the World Health Organization reported on the instability of ACTH in whole blood at RT, but without specifying the duration of stability (34). In 2010, the German Society for Clinical Chemistry and Laboratory Medicine suggested stability in whole blood for a large range from 1 to 4 h at RT, but without providing recommendations for the refrigerated condition (35). However, the conclusions of the two latter reports were based on the review of only 3 and 4 reports, respectively, whereas our systematic review encompassed data from 9 studies, all conducted since 2010.

Our work has also limitations that warrant discussion. Firstly, our search strategy was limited to the PubMed database and to articles published in English. Therefore, it is possible that we may have overlooked some eligible stability studies, although PubMed is one of the largest biomedical bibliographic databases. Secondly, the number of the selected studies was quite limited, making it statistically difficult to generate one pooled estimate in a meta-analysis and to study the possible moderators. Thirdly, our review did not permit to draw conclusions regarding the potential advantages of tubes containing both EDTA and protease inhibitors. Two studies provided data on the stability in such tubes, but we excluded these studies since they did not report directly the PD% (29,30). Casati et al. conducted a direct comparison between storage in EDTA versus EDTA-aprotinin tubes (30). They observed a higher decrease in ACTH concentrations with EDTA-aprotinin tubes compared to EDTA tubes after 2 h of storage in ice/water, but without statistical analysis of the difference (30). Unfortunately, no data were available for storage durations greater than 6 h at RT in EDTA-aprotinin tubes, for which ACTH degradation is unambiguously significant in EDTA tubes.

In summary, our study provides a comprehensive assessment of studies reporting on ACTH stability in uncentrifuged tubes. By demonstrating the stability of ACTH in uncentrifuged EDTA tubes for 6 h at RT and at least 8 h under refrigeration, our findings can assist clinical laboratories in reviewing their acceptance criteria for sample transport regarding time and temperature. Nonetheless, it is important to acknowledge that transport time and temperature constitute only one aspect of the conditions requiring careful management during the preanalytical phase (36). Other variables, such as recording the timing of blood sampling or hemolysis, deserve special attention for ACTH analysis (5).

Acknowledgments

The authors are grateful to Suzanne Rankin (CHU Dijon Bourgogne) for the language revision of the article.

Notes

[1] Conflicts of interest Potential conflict of interest

None declared.

Data availability statement

The data generated and analyzed in the presented study are available from the corresponding author on request.

References

1 

Fleseriu M, Auchus R, Bancos I, Ben-Shlomo A, Bertherat J, Biermasz NR, et al. Consensus on diagnosis and management of Cushing’s disease: A guideline update. Lancet Diabetes Endocrinol. 2021;9:847–75. https://doi.org/10.1016/S2213-8587(21)00235-7 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/34687601

2 

Bornstein SR, Allolio B, Arlt W, Barthel A, Don-Wauchope A, Hammer GD, et al. Diagnosis and treatment of primary adrenal insufficiency: An Endocrine Society Clinical practice guideline. J Clin Endocrinol Metab. 2016;101:364–89. https://doi.org/10.1210/jc.2015-1710 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/26760044

3 

Owen CA. Leukocyte cell surface proteinases: regulation of expression, functions, and mechanisms of surface localization. Int J Biochem Cell Biol. 2008;40:1246–72. https://doi.org/10.1016/j.biocel.2008.01.020 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/18329945

4 

Hillebrand JJ, Zhou L, Marcinkus MA, Datwyler M, Gawel SH, Martens F, et al. Instability of corticotropin during long-term storage - myth or reality? Clin Chem Lab Med. 2021;60:60–5. https://doi.org/10.1515/cclm-2021-0818 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/34643074

5 

Lippi G, Blanckaert N, Bonini P, Green S, Kitchen S, Palicka V, et al. Haemolysis: an overview of the leading cause of unsuitable specimens in clinical laboratories. Clin Chem Lab Med. 2008;46:764–72. https://doi.org/10.1515/CCLM.2008.170 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/18601596

6 

Bosse M, Bayart JL. Crioplast is a reliable device to ensure pre-analytical stability of adrenocorticotrophin (ACTH). Clin Chem Lab Med. 2024;62:e123–5. https://doi.org/10.1515/cclm-2024-0043 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/38366955

7 

Dong L, Hao T, Chen J, Chai Y, Jia Z, Tuo W, et al. Research on the stability changes in expert consensus of the ACTH detection preprocessing scheme. JLM. 2024;48:77–81. https://doi.org/10.1515/labmed-2023-0086

8 

Lippi G, Simundic AM; European Federation for Clinical Chemistry and Laboratory Medicine (EFLM) Working Group for Preanalytical Phase (WG-PRE). The EFLM strategy for harmonization of the preanalytical phase. Clin Chem Lab Med. 2018;56:1660–6. https://doi.org/10.1515/cclm-2017-0277 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/28593910

9 

Page MJ, McKenzie JE, Bossuyt PM, Boutron I, Hoffmann TC, Mulrow CD, et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ. 2021;372(71): https://doi.org/10.1136/bmj.n71 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/33782057

10 

Gómez Rioja R, Martínez Espartosa D, Segovia M, Ibarz M, Llopis MA, Bauça JM, et al. Laboratory sample stability. Is it possible to define a consensus stability function? An example of five blood magnitudes. Clin Chem Lab Med. 2018;56:1806–18. https://doi.org/10.1515/cclm-2017-1189 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/29729140

11 

BD Vacutainer EDTA Tubes. Available from:https://www.bd.com/en-us/products-and-solutions/products/product-page.367863. Accessed Apr 1st 2024.

12 

Greiner Bio-One. Available from:https://www.gbo.com/. Accessed Apr 1st 2024.

14 

Shi J, Luo D, Weng H, Zeng XT, Lin L, Chu H, et al. Optimally estimating the sample standard deviation from the five-number summary. Res Synth Methods. 2020;11:641–54. https://doi.org/10.1002/jrsm.1429 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/32562361

15 

International Standardization Organisation. ISO 5725-6:1994. Available from:https://www.iso.org/standard/11837.html. Accessed Apr 1st 2024.

16 

Aarsand A, Fernandez-Calle P, Webster C. EFLM Biological Variation. Available from:https://biologicalvariation.eu/. Accessed Apr 1st 2024.

17 

Desirable Biological Variation Database specifications - Westgard. Available from:https://www.westgard.com/biodatabase1.htm. Accessed Apr 1st 2024.

18 

Wu ZQ, Xu HG. Preanalytical stability of adrenocorticotropic hormone depends on both time to centrifugation and temperature. J Clin Lab Anal. 2017;31:e22081. https://doi.org/10.1002/jcla.22081 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/27735096

19 

Jane Ellis M, Livesey JH, Evans MJ. Hormone stability in human whole blood. Clin Biochem. 2003;36:109–12. https://doi.org/10.1016/S0009-9120(02)00440-X PubMed: http://www.ncbi.nlm.nih.gov/pubmed/12633759

20 

Christensen M, Madsen RF, Møller LR, Knudsen CS, Samson MH. Whole blood samples for adrenocorticotrophic hormone measurement can be stored at room temperature for 4 hours. Scand J Clin Lab Invest. 2016;76:653–6. https://doi.org/10.1080/00365513.2016.1230887 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/27701894

21 

Reisch N, Reincke M, Bidlingmaier M. Preanalytical stability of adrenocorticotropic hormone depends on time to centrifugation rather than temperature. Clin Chem. 2007;53:358–9. https://doi.org/10.1373/clinchem.2006.080622 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/17259248

22 

Chakera AJ, McDonald TJ, Knight BA, Vaidya B, Jones AG. Current laboratory requirements for adrenocorticotropic hormone and renin/aldosterone sample handling are unnecessarily restrictive. Clin Med (Lond). 2017;17:18–21. https://doi.org/10.7861/clinmedicine.17-1-18 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/28148573

23 

Turkon H, Toprak B, Yalcin H, Colak A, Ozturk N. The effectiveness of temperature versus aprotinin in maintaining the preanalytical stability of adrenocorticotrophin. Lab Med. 2016;47:279–82. https://doi.org/10.1093/labmed/lmw027 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/27593170

24 

Evans MJ, Livesey JH, Ellis MJ, Yandle TG. Effect of anticoagulants and storage temperatures on stability of plasma and serum hormones. Clin Biochem. 2001;34:107–12. https://doi.org/10.1016/S0009-9120(01)00196-5 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/11311219

25 

Schneider S, Brümmer V, Carnahan H, Dubrowski A, Askew CD, Strüder HK. Stress hormone stability: processing of blood samples collected during parabolic flight. A pre-flight comparison of different protocols. Clin Biochem. 2007;40:1332–5. https://doi.org/10.1016/j.clinbiochem.2007.07.022 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/17888897

26 

Wu ZQ, Xu HG. Comparison of two commercial quality control sera for adrenocorticotropin (ACTH) used in Elecsys® immunoassay system. J Clin Lab Anal. 2019;33:e22618. https://doi.org/10.1002/jcla.22618 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/30006935

27 

Hillebrand JJ, Heijboer AC, Endert E. Effects of repeated freeze-thaw cycles on endocrine parameters in plasma and serum. Ann Clin Biochem. 2017;54:289–92. https://doi.org/10.1177/0004563216657361 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/27303059

28 

Livesey JH, Dolamore B. Stability of plasma adrenocorticotrophic hormone (ACTH): influence of hemolysis, rapid chilling, time, and the addition of a maleimide. Clin Biochem. 2010;43:1478–80. https://doi.org/10.1016/j.clinbiochem.2010.09.020 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/20875812

29 

Mechanic L, Mendez A, Merrill L, Rogers J, Layton M, Todd D, et al. Planned variation in preanalytical conditions to evaluate biospecimen stability in the National Children’s Study (NCS). Clin Chem Lab Med. 2013;51:2287–94. https://doi.org/10.1515/cclm-2013-0454 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/23924524

30 

Casati M, Cappellani A, Perlangeli V, Ippolito S, Pittalis S, Romano R, et al. Adrenocorticotropic hormone stability in preanalytical phase depends on temperature and proteolytic enzyme inhibitor. Clin Chem Lab Med. 2013;51:e45–7. https://doi.org/10.1515/cclm-2012-0431 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/23023695

31 

Lambert A, Frost J, Ratcliffe WA, Robertson WR. On the stability in vitro of bioactive human adrenocorticotrophin in blood and plasma. Clin Endocrinol (Oxf). 1985;23:253–61. https://doi.org/10.1111/j.1365-2265.1985.tb00221.x PubMed: http://www.ncbi.nlm.nih.gov/pubmed/3000649

32 

Diver MJ, Hughes JG, Hutton JL, West CR, Hipkin LJ. The long-term stability in whole blood of 14 commonly-requested hormone analytes. Ann Clin Biochem. 1994;31:561–5. https://doi.org/10.1177/000456329403100606 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/7880075

33 

Cornes M, Simundic AM, Cadamuro J, Costelloe SJ, Baird G, Kristensen GBB, et al. The CRESS checklist for reporting stability studies: on behalf of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group for the Preanalytical Phase (WG-PRE). Clin Chem Lab Med. 2020;59:59–69. https://doi.org/10.1515/cclm-2020-0061 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/32710715

34 

Technology WHODI and L. Use of anticoagulants in diagnostic laboratory investigations. 2002. Available from:https://iris.who.int/handle/10665/65957. Accessed Apr 1st 2024.

35 

Guder WG, da Fonseca-Wollheim F, Heil W, Schmitt Y, Töpfer G, Wisser H, et al. Quality of diagnostic samples. Recommendations of the working group on preanalytical quality of the German Society for Clinical Chemistry and Laboratory Medicine. Darmstadt: GIT, 2001.

36 

Vermeersch P, Frans G, von Meyer A, Costelloe S, Lippi G, Simundic AM. How to meet ISO15189:2012 pre-analytical requirements in clinical laboratories? A consensus document by the EFLM WG-PRE. Clin Chem Lab Med. 2021;59:1047–61. https://doi.org/10.1515/cclm-2020-1859 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/33554545

37 

Nandakumar V, Paul Theobald J, Algeciras-Schimnich A. Evaluation of plasma ACTH stability using the Roche Elecsys immunoassay. Clin Biochem. 2020;81:59–62. https://doi.org/10.1016/j.clinbiochem.2020.04.004 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/32315613

38 

Oddoze C, Lombard E, Portugal H. Stability study of 81 analytes in human whole blood, in serum and in plasma. Clin Biochem. 2012;45:464–9. https://doi.org/10.1016/j.clinbiochem.2012.01.012 PubMed: http://www.ncbi.nlm.nih.gov/pubmed/22285385


This display is generated from NISO JATS XML with jats-html.xsl. The XSLT engine is libxslt.