Skoči na glavni sadržaj

Izvorni znanstveni članak

https://doi.org/10.55378/rv.50.1.3

Dual-energy CT in polytrauma

Alen Udovičić ; Department of Radiology, University Hospital Centre Zagreb, Croatia
Bepo Vasić ; Department of Radiology, University Hospital Centre Zagreb, Croatia
Marijana Pervan ; Department of Radiology, University Hospital Centre Zagreb, Croatia


Puni tekst: engleski pdf 1.278 Kb

verzije

str. 13-16

preuzimanja: 0

citiraj


Sažetak

Aim: To evaluate dual-energy CT (DECT) whole-body polytrauma protocols and quantify radiation dose reduction compared with a standard multiphase CT protocol.
Materials and Methods: This retrospective single-centre study included polytrauma patients, stratified into three groups: standard CT (n = 255), DECT-stable (n = 164), and DECT-unstable (n = 19). Radiation dose was assessed using the dose-length product (DLP).
Results: Median DLP was 5940 mGy·cm (standard), 2671 mGy·cm (DECT stable), and 3247.5 mGy·cm (DECT unstable), corresponding to dose reductions of 55.0% and 45.3%, respectively.
Conclusion: DECT protocols enable substantial radiation dose reduction while maintaining clinical workflow efficiency.

Ključne riječi

polytrauma; computed tomography; dual-energy CT; split-bolus; virtual non-contrast; radiation dose; dose-length product (DLP)

Hrčak ID:

347486

URI

https://hrcak.srce.hr/347486

Datum izdavanja:

5.5.2026.

Podaci na drugim jezicima: hrvatski

Posjeta: 0 *