Skoči na glavni sadržaj

Izvorni znanstveni članak

https://doi.org/10.1080/00051144.2017.1372122

Frequency synchronization of a single-phase grid-connected DC/AC inverter using a double integration method

Jean Marie Vianney Bikorimana ; Department of Electrical Engineering, Ghent University, Gent, Belgium
Mohannad Jabbar Mnati ; Department of Electrical Engineering, Ghent University, Gent, Belgium
Alex Van den Bossche ; Department of Electrical Engineering, Ghent University, Gent, Belgium


Puni tekst: engleski pdf 1.137 Kb

str. 141-146

preuzimanja: 492

citiraj


Sažetak

Many traditional grids have started to integrate the DC/AC inverters in their networks. This requires a good control to enhance the power quality. The grid frequency behaviour is one of the principal indicators that reveal the power quality. Therefore, it must be strongly controlled.
Up to now, the most popular frequency synchronization method is based on phase-locked loop (PLL) control. It is known that setting a current proportional to voltage does not work well and it creates a negative resistor in a wide frequency range because the circuit is not passive.
This paper presents an alternative idea of synchronization of a single-phase grid-connected DC/AC inverter by using a double integration method. It is simpler than PLL since it needs neither a phase comparator, nor a local oscillator. It provides a signal in phase with the current. The art of the method is how to remove the integrating constants without degrading the signal.

Ključne riječi

Frequency control; DC/AC inverter; DISM

Hrčak ID:

203351

URI

https://hrcak.srce.hr/203351

Datum izdavanja:

1.12.2017.

Posjeta: 1.192 *