Skoči na glavni sadržaj

Prethodno priopćenje

https://doi.org/10.14256/JCE.3036.2020

Fragility and robustness analysis of a multistorey RC building

Miloš Čokić
Radomir Folić


Puni tekst: hrvatski pdf 616 Kb

str. 27-44

preuzimanja: 499

citiraj

Puni tekst: engleski pdf 608 Kb

str. 27-44

preuzimanja: 416

citiraj


Sažetak

The robustness of a reinforced concrete (RC) five-storey building (frame system stiffened by walls) is analysed in the paper. A high ductility class structure is designed in accordance with structural Eurocodes. The response of the structure to eight different scenarios of the ground floor vertical element loss is analysed. Nonlinear Static Analysis (NSA) and Nonlinear Dynamic Analysis (NDA) methods are used for the robustness analysis. Fragility curves of the building are derived from statistical analysis of these results. The values obtained through NSA and NDA, damage limit states of the system, and fragility curves, are compared. The influence of the position of the removed element on robustness of the structure is also analysed.

Ključne riječi

RC structure of a building; frame structure stiffened by walls; robustness; fragility; progressive collapse; nonlinear static analysis; nonlinear dynamic analysis; damage limit states

Hrčak ID:

252429

URI

https://hrcak.srce.hr/252429

Datum izdavanja:

10.2.2021.

Podaci na drugim jezicima: hrvatski

Posjeta: 2.192 *