hrcak mascot   Srce   HID

Izvorni znanstveni članak
https://doi.org/10.5562/cca1784

PEDOT Modified Carbon Paste Microelectrodes for Scanning Electrochemical Microscopy

Balazs Csoka ; Department of Analytical and Environmental Chemistry, Faculty of Sciences, University of Pécs, Ifjúság útja 6, H-7624 Pécs, Hungary
Zineb Mekhalif ; Laboratory of Chemistry and Electrochemistry of Surfaces, University of Namur (FUNDP), Rue de Bruxelles 61, B-5000 Namur, Belgium

Puni tekst: engleski, pdf (6 MB) str. 407-412 preuzimanja: 898* citiraj
APA 6th Edition
Csoka, B. i Mekhalif, Z. (2011). PEDOT Modified Carbon Paste Microelectrodes for Scanning Electrochemical Microscopy. Croatica Chemica Acta, 84 (3), 407-412. https://doi.org/10.5562/cca1784
MLA 8th Edition
Csoka, Balazs i Zineb Mekhalif. "PEDOT Modified Carbon Paste Microelectrodes for Scanning Electrochemical Microscopy." Croatica Chemica Acta, vol. 84, br. 3, 2011, str. 407-412. https://doi.org/10.5562/cca1784. Citirano 25.02.2021.
Chicago 17th Edition
Csoka, Balazs i Zineb Mekhalif. "PEDOT Modified Carbon Paste Microelectrodes for Scanning Electrochemical Microscopy." Croatica Chemica Acta 84, br. 3 (2011): 407-412. https://doi.org/10.5562/cca1784
Harvard
Csoka, B., i Mekhalif, Z. (2011). 'PEDOT Modified Carbon Paste Microelectrodes for Scanning Electrochemical Microscopy', Croatica Chemica Acta, 84(3), str. 407-412. https://doi.org/10.5562/cca1784
Vancouver
Csoka B, Mekhalif Z. PEDOT Modified Carbon Paste Microelectrodes for Scanning Electrochemical Microscopy. Croatica Chemica Acta [Internet]. 2011 [pristupljeno 25.02.2021.];84(3):407-412. https://doi.org/10.5562/cca1784
IEEE
B. Csoka i Z. Mekhalif, "PEDOT Modified Carbon Paste Microelectrodes for Scanning Electrochemical Microscopy", Croatica Chemica Acta, vol.84, br. 3, str. 407-412, 2011. [Online]. https://doi.org/10.5562/cca1784

Sažetak
Only one measuring tip was used in three different modes of operation of the Scanning Electrochemical
Microscope (feed-back mode, generation-collection mode, potentiometry) to collect chemical information
about copper targets. The tip was formed from 5 and 25 μm diameter conventional platinum
microdisk electrode by etching a cavity, then electrochemically depositing poly(3,4-ethylenedioxythiophene)
(PEDOT) layer doped with hexacyanoferrate and finally filling with modified carbon paste
based Cu2+ sensing layer. The preparation and electrochemical working parameters of this kind of solidcontact
microelectrodes are discussed as well as SECM applications for copper detection is reported.