Otkrivanje dehiscencije uporabom video crteža obogaćenih slika prikupljenih intraoralnim detektorom vrste CCD(*}

Allan G. Farman ; School of Dentistry The University of Louisville, Louisville, Kentucky 40292, USA
John A. Benkovich ; School of Dentistry The University of Louisville, Louisville, Kentucky 40292, USA
Taeko T. Farman ; School of Dentistry The University of Louisville, Louisville, Kentucky 40292, USA

Puni tekst: hrvatski, pdf (13 MB) str. 537-546 preuzimanja: 161* citiraj
APA 6th Edition
Farman, A.G., Benkovich, J.A. i Farman, T.T. (1998). Otkrivanje dehiscencije uporabom video crteža obogaćenih slika prikupljenih intraoralnim detektorom vrste CCD(*}. Acta stomatologica Croatica, 32 (4), 537-546. Preuzeto s https://hrcak.srce.hr/98247
MLA 8th Edition
Farman, Allan G., et al. "Otkrivanje dehiscencije uporabom video crteža obogaćenih slika prikupljenih intraoralnim detektorom vrste CCD(*}." Acta stomatologica Croatica, vol. 32, br. 4, 1998, str. 537-546. https://hrcak.srce.hr/98247. Citirano 07.03.2021.
Chicago 17th Edition
Farman, Allan G., John A. Benkovich i Taeko T. Farman. "Otkrivanje dehiscencije uporabom video crteža obogaćenih slika prikupljenih intraoralnim detektorom vrste CCD(*}." Acta stomatologica Croatica 32, br. 4 (1998): 537-546. https://hrcak.srce.hr/98247
Harvard
Farman, A.G., Benkovich, J.A., i Farman, T.T. (1998). 'Otkrivanje dehiscencije uporabom video crteža obogaćenih slika prikupljenih intraoralnim detektorom vrste CCD(*}', Acta stomatologica Croatica, 32(4), str. 537-546. Preuzeto s: https://hrcak.srce.hr/98247 (Datum pristupa: 07.03.2021.)
Vancouver
Farman AG, Benkovich JA, Farman TT. Otkrivanje dehiscencije uporabom video crteža obogaćenih slika prikupljenih intraoralnim detektorom vrste CCD(*}. Acta stomatologica Croatica [Internet]. 1998 [pristupljeno 07.03.2021.];32(4):537-546. Dostupno na: https://hrcak.srce.hr/98247
IEEE
A.G. Farman, J.A. Benkovich i T.T. Farman, "Otkrivanje dehiscencije uporabom video crteža obogaćenih slika prikupljenih intraoralnim detektorom vrste CCD(*}", Acta stomatologica Croatica, vol.32, br. 4, str. 537-546, 1998. [Online]. Dostupno na: https://hrcak.srce.hr/98247. [Citirano: 07.03.2021.]
Puni tekst: engleski, pdf (13 MB) str. 537-546 preuzimanja: 170* citiraj
APA 6th Edition
Farman, A.G., Benkovich, J.A. i Farman, T.T. (1998). Dehiscence Detection Using Video Prints of Enhanced Images Acquired with a CCD Intra-Oral Detector. Acta stomatologica Croatica, 32 (4), 537-546. Preuzeto s https://hrcak.srce.hr/98247
MLA 8th Edition
Farman, Allan G., et al. "Dehiscence Detection Using Video Prints of Enhanced Images Acquired with a CCD Intra-Oral Detector." Acta stomatologica Croatica, vol. 32, br. 4, 1998, str. 537-546. https://hrcak.srce.hr/98247. Citirano 07.03.2021.
Chicago 17th Edition
Farman, Allan G., John A. Benkovich i Taeko T. Farman. "Dehiscence Detection Using Video Prints of Enhanced Images Acquired with a CCD Intra-Oral Detector." Acta stomatologica Croatica 32, br. 4 (1998): 537-546. https://hrcak.srce.hr/98247
Harvard
Farman, A.G., Benkovich, J.A., i Farman, T.T. (1998). 'Dehiscence Detection Using Video Prints of Enhanced Images Acquired with a CCD Intra-Oral Detector', Acta stomatologica Croatica, 32(4), str. 537-546. Preuzeto s: https://hrcak.srce.hr/98247 (Datum pristupa: 07.03.2021.)
Vancouver
Farman AG, Benkovich JA, Farman TT. Dehiscence Detection Using Video Prints of Enhanced Images Acquired with a CCD Intra-Oral Detector. Acta stomatologica Croatica [Internet]. 1998 [pristupljeno 07.03.2021.];32(4):537-546. Dostupno na: https://hrcak.srce.hr/98247
IEEE
A.G. Farman, J.A. Benkovich i T.T. Farman, "Dehiscence Detection Using Video Prints of Enhanced Images Acquired with a CCD Intra-Oral Detector", Acta stomatologica Croatica, vol.32, br. 4, str. 537-546, 1998. [Online]. Dostupno na: https://hrcak.srce.hr/98247. [Citirano: 07.03.2021.]

Sažetak
Ciljevi: Radiografsko određivanje dehiscencije u alveolarnoj kosti koja graniči sa zubom problematično je ako se ne događa u vremenskim razmacima i ne može biti prikazano radiografskom suptrakcijom. Ova je studija provedena kako bi se ustanovilo može li obogaćenje digitalno prikupljenih slika omogućiti da se otkriju ta stanja. Metode: Kao ispitni model poslužili su svježi, nebalzamirani mrtvi zubni uzorci. Zabilježena su područja prirodne dehiscencije. U slučaju izostanka prirodne dehiscencije, defekti su stvarani u regijama bukalne ili labijalno alveolarne kosti skalpelom veličine 15. Tako uzrokovani defekti bili su kategorizirani kao “prirodna simulacija ” ili “dobro definirani”. Ostala područja ostavljena su netaknutima da posluže kao normalne kontrolne vrijednosti. Periapikalne radiografije bile su izrađene sustavom RVG-S® s generatorom X-zraka Iris 70® (Trophy Radiologie, Vincennes, France). Projekciona geometrija i parametri ekspozicije bili su održavani stalnima. Šestorica stomatologa bili su promatrači. Oni su svaki zasebno, pod jednakim uvjetima promatranja ispitali otisnute video crteže obogaćenih slika.
Rezultati: Učinak postojanja i tipa defekata alveolarne kosti bio je statistički značajan (p<0,002), no način obogaćivanja kontrasta slike
nije imao veći utjecaj (p>0,05). Ukupna osjetljivost za detekciju koštanih defekata bila je samo 30%, uz specifičnost od 79% i ukupnu točnost od 48%. Zaključci: Neovisno o načinu obogaćivanja kontrasta, video ispisi digitalnog očitavanja slika zuba okruženog s kosti pokazali su malu osjetljivost za detekciju prirodno nastalih pojava dehiscencije i za izrađene defekte u svrhu simuliranja toga stanja.

Ključne riječi
zjapljenje; obogaćivanje digitalne slike; periodontium; dentalna radiografija