Izvorni znanstveni članak

Changes of the retentional force ceka intraoral anchors caused by the repeated removals

Miodrag M. Nastić ; Klinika za stomatološku protetiku, Stomatološkog fakulteta Univerziteta u Beogradu, Beograd, Srbija

Puni tekst: srpski, pdf (8 MB) str. 127-136 preuzimanja: 491* citiraj
APA 6th Edition
Nastić, M.M. (1989). Promene retencione sile ceka intrakoronarnih sidara izazvane višestrukim razdvajanjem patrice i matrice. Acta stomatologica Croatica, 23 (2), 127-136. Preuzeto s https://hrcak.srce.hr/101304
MLA 8th Edition
Nastić, Miodrag M.. "Promene retencione sile ceka intrakoronarnih sidara izazvane višestrukim razdvajanjem patrice i matrice." Acta stomatologica Croatica, vol. 23, br. 2, 1989, str. 127-136. https://hrcak.srce.hr/101304. Citirano 07.03.2021.
Chicago 17th Edition
Nastić, Miodrag M.. "Promene retencione sile ceka intrakoronarnih sidara izazvane višestrukim razdvajanjem patrice i matrice." Acta stomatologica Croatica 23, br. 2 (1989): 127-136. https://hrcak.srce.hr/101304
Harvard
Nastić, M.M. (1989). 'Promene retencione sile ceka intrakoronarnih sidara izazvane višestrukim razdvajanjem patrice i matrice', Acta stomatologica Croatica, 23(2), str. 127-136. Preuzeto s: https://hrcak.srce.hr/101304 (Datum pristupa: 07.03.2021.)
Vancouver
Nastić MM. Promene retencione sile ceka intrakoronarnih sidara izazvane višestrukim razdvajanjem patrice i matrice. Acta stomatologica Croatica [Internet]. 1989 [pristupljeno 07.03.2021.];23(2):127-136. Dostupno na: https://hrcak.srce.hr/101304
IEEE
M.M. Nastić, "Promene retencione sile ceka intrakoronarnih sidara izazvane višestrukim razdvajanjem patrice i matrice", Acta stomatologica Croatica, vol.23, br. 2, str. 127-136, 1989. [Online]. Dostupno na: https://hrcak.srce.hr/101304. [Citirano: 07.03.2021.]

Sažetak
A retainer should provide force capable of securing the position of the partial denture an still not damaging the periodontium of the abutment teeth. It’s almost generally accepted that the retentional force should not be greater than 10 N nor weaker than 5 N. This study was designed to measure the forces required to disconnect parts of CEKA intracoronal anchors initialy and repeatedly up to 50000 cycles. The results are compared with suggested values. It was found that the initial force exeeded 10 N. A fter repeated removals retentional force decreased, but never under values of 5 N.

Ključne riječi
CEKA intracorolal anchor; retainer; abutment teeth

Hrčak ID: 101304