High voltage coreless transformer for power quality measurement at medium voltage level
Zoran Mitrović
; University of Novi Sad, Faculty of Technical Sciences, Trg Dositeja Obradovića 6, 21000 Novi Sad, Serbia
Dušan Čomić
; EPS Elektrovojvodina, Bulevar oslobođenja 100, 21000 Novi Sad, Serbia
Slobodan Milovančev
; University of Novi Sad, Faculty of Technical Sciences, Trg Dositeja Obradovića 6, 21000 Novi Sad, Serbia
Dragan Pejić
; University of Novi Sad, Faculty of Technical Sciences, Trg Dositeja Obradovića 6, 21000 Novi Sad, Serbia
APA 6th Edition Mitrović, Z., Čomić, D., Milovančev, S. i Pejić, D. (2016). High voltage coreless transformer for power quality measurement at medium voltage level. Tehnički vjesnik, 23 (5), 1245-1250. https://doi.org/10.17559/TV-20150318102342
MLA 8th Edition Mitrović, Zoran, et al. "High voltage coreless transformer for power quality measurement at medium voltage level." Tehnički vjesnik, vol. 23, br. 5, 2016, str. 1245-1250. https://doi.org/10.17559/TV-20150318102342. Citirano 02.03.2021.
Chicago 17th Edition Mitrović, Zoran, Dušan Čomić, Slobodan Milovančev i Dragan Pejić. "High voltage coreless transformer for power quality measurement at medium voltage level." Tehnički vjesnik 23, br. 5 (2016): 1245-1250. https://doi.org/10.17559/TV-20150318102342
Harvard Mitrović, Z., et al. (2016). 'High voltage coreless transformer for power quality measurement at medium voltage level', Tehnički vjesnik, 23(5), str. 1245-1250. https://doi.org/10.17559/TV-20150318102342
Vancouver Mitrović Z, Čomić D, Milovančev S, Pejić D. High voltage coreless transformer for power quality measurement at medium voltage level. Tehnički vjesnik [Internet]. 2016 [pristupljeno 02.03.2021.];23(5):1245-1250. https://doi.org/10.17559/TV-20150318102342
IEEE Z. Mitrović, D. Čomić, S. Milovančev i D. Pejić, "High voltage coreless transformer for power quality measurement at medium voltage level", Tehnički vjesnik, vol.23, br. 5, str. 1245-1250, 2016. [Online]. https://doi.org/10.17559/TV-20150318102342
APA 6th Edition Mitrović, Z., Čomić, D., Milovančev, S. i Pejić, D. (2016). Transformator bez jezgre za mjerenje kvalitete električne energije na srednjem naponu. Tehnički vjesnik, 23 (5), 1245-1250. https://doi.org/10.17559/TV-20150318102342
MLA 8th Edition Mitrović, Zoran, et al. "Transformator bez jezgre za mjerenje kvalitete električne energije na srednjem naponu." Tehnički vjesnik, vol. 23, br. 5, 2016, str. 1245-1250. https://doi.org/10.17559/TV-20150318102342. Citirano 02.03.2021.
Chicago 17th Edition Mitrović, Zoran, Dušan Čomić, Slobodan Milovančev i Dragan Pejić. "Transformator bez jezgre za mjerenje kvalitete električne energije na srednjem naponu." Tehnički vjesnik 23, br. 5 (2016): 1245-1250. https://doi.org/10.17559/TV-20150318102342
Harvard Mitrović, Z., et al. (2016). 'Transformator bez jezgre za mjerenje kvalitete električne energije na srednjem naponu', Tehnički vjesnik, 23(5), str. 1245-1250. https://doi.org/10.17559/TV-20150318102342
Vancouver Mitrović Z, Čomić D, Milovančev S, Pejić D. Transformator bez jezgre za mjerenje kvalitete električne energije na srednjem naponu. Tehnički vjesnik [Internet]. 2016 [pristupljeno 02.03.2021.];23(5):1245-1250. https://doi.org/10.17559/TV-20150318102342
IEEE Z. Mitrović, D. Čomić, S. Milovančev i D. Pejić, "Transformator bez jezgre za mjerenje kvalitete električne energije na srednjem naponu", Tehnički vjesnik, vol.23, br. 5, str. 1245-1250, 2016. [Online]. https://doi.org/10.17559/TV-20150318102342
Sažetak Measurement of grid voltage harmonic components is an important part of power quality measurements. Current high voltage transformers with iron core are not linear and cannot easily be used for accurate measurement of "polluted" voltages in wide frequency range. In this paper, design details of a new coreless voltage transformer for power quality measurement are given. As a proof of concept, two transformers, shielded and unshielded, were realized. Measurement results of transformer parameters, results of transformer behaviour simulation and results of transformer linearity measurement are presented. These results show that the proposed transformer can be used for power quality measurement at low and medium voltage levels (up to 35 kV) with harmonic voltages up to 50th order.