Experimental and numerical research of mechanical behaviour of titanium alloy hip implant
Katarina Čolić
; University of Belgrade, Innovation Center of Faculty of Mechanical Engineering, Kraljice Marije 16, 11 000 Belgrade, Serbia
Aleksandar Sedmak
; University of Belgrade, Faculty of Mechanical Engineering, Kraljice Marije 16, 11 000 Belgrade, Serbia
Kaled Legweel
; University of Belgrade, Faculty of Mechanical Engineering, Kraljice Marije 16, 11 000 Belgrade, Serbia
Miloš Milošević
; University of Belgrade, Innovation Center of Faculty of Mechanical Engineering, Kraljice Marije 16, 11 000 Belgrade, Serbia
Nenad Mitrović
; University of Belgrade, Faculty of Mechanical Engineering, Kraljice Marije 16, 11 000 Belgrade, Serbia
Žarko Mišković
orcid.org/0000-0003-0513-6540
; University of Belgrade, Faculty of Mechanical Engineering, Kraljice Marije 16, 11 000 Belgrade, Serbia
Sergej Hloch
orcid.org/0000-0003-4066-0620
; Faculty of Manufacturing Technologies of Technical University of Kosice with seat in Presov, Bayerova 1, 080 01 Prešov, Slovak Republic
APA 6th Edition Čolić, K., Sedmak, A., Legweel, K., Milošević, M., Mitrović, N., Mišković, Ž. i Hloch, S. (2017). Experimental and numerical research of mechanical behaviour of titanium alloy hip implant. Tehnički vjesnik, 24 (3), 709-713. https://doi.org/10.17559/TV-20160219132016
MLA 8th Edition Čolić, Katarina, et al. "Experimental and numerical research of mechanical behaviour of titanium alloy hip implant." Tehnički vjesnik, vol. 24, br. 3, 2017, str. 709-713. https://doi.org/10.17559/TV-20160219132016. Citirano 24.02.2021.
Chicago 17th Edition Čolić, Katarina, Aleksandar Sedmak, Kaled Legweel, Miloš Milošević, Nenad Mitrović, Žarko Mišković i Sergej Hloch. "Experimental and numerical research of mechanical behaviour of titanium alloy hip implant." Tehnički vjesnik 24, br. 3 (2017): 709-713. https://doi.org/10.17559/TV-20160219132016
Harvard Čolić, K., et al. (2017). 'Experimental and numerical research of mechanical behaviour of titanium alloy hip implant', Tehnički vjesnik, 24(3), str. 709-713. https://doi.org/10.17559/TV-20160219132016
Vancouver Čolić K, Sedmak A, Legweel K, Milošević M, Mitrović N, Mišković Ž i sur. Experimental and numerical research of mechanical behaviour of titanium alloy hip implant. Tehnički vjesnik [Internet]. 2017 [pristupljeno 24.02.2021.];24(3):709-713. https://doi.org/10.17559/TV-20160219132016
IEEE K. Čolić, et al., "Experimental and numerical research of mechanical behaviour of titanium alloy hip implant", Tehnički vjesnik, vol.24, br. 3, str. 709-713, 2017. [Online]. https://doi.org/10.17559/TV-20160219132016
APA 6th Edition Čolić, K., Sedmak, A., Legweel, K., Milošević, M., Mitrović, N., Mišković, Ž. i Hloch, S. (2017). Eksperimentalno i numeričko istraživanje mehaničkog ponašanja umjetnog kuka od legure titana. Tehnički vjesnik, 24 (3), 709-713. https://doi.org/10.17559/TV-20160219132016
MLA 8th Edition Čolić, Katarina, et al. "Eksperimentalno i numeričko istraživanje mehaničkog ponašanja umjetnog kuka od legure titana." Tehnički vjesnik, vol. 24, br. 3, 2017, str. 709-713. https://doi.org/10.17559/TV-20160219132016. Citirano 24.02.2021.
Chicago 17th Edition Čolić, Katarina, Aleksandar Sedmak, Kaled Legweel, Miloš Milošević, Nenad Mitrović, Žarko Mišković i Sergej Hloch. "Eksperimentalno i numeričko istraživanje mehaničkog ponašanja umjetnog kuka od legure titana." Tehnički vjesnik 24, br. 3 (2017): 709-713. https://doi.org/10.17559/TV-20160219132016
Harvard Čolić, K., et al. (2017). 'Eksperimentalno i numeričko istraživanje mehaničkog ponašanja umjetnog kuka od legure titana', Tehnički vjesnik, 24(3), str. 709-713. https://doi.org/10.17559/TV-20160219132016
Vancouver Čolić K, Sedmak A, Legweel K, Milošević M, Mitrović N, Mišković Ž i sur. Eksperimentalno i numeričko istraživanje mehaničkog ponašanja umjetnog kuka od legure titana. Tehnički vjesnik [Internet]. 2017 [pristupljeno 24.02.2021.];24(3):709-713. https://doi.org/10.17559/TV-20160219132016
IEEE K. Čolić, et al., "Eksperimentalno i numeričko istraživanje mehaničkog ponašanja umjetnog kuka od legure titana", Tehnički vjesnik, vol.24, br. 3, str. 709-713, 2017. [Online]. https://doi.org/10.17559/TV-20160219132016
Sažetak Experimental and numerical research of mechanical behaviour of hip replacement implant is presented. Experimental analysis was based on standard methods for testing mechanical properties and application of Digital Image Correlation (DIC) technique, while the Finite Element Method (FEM) was used for numerical simulation. A hip prosthesis extracted from a patient after revision surgery was used as the specimen. An adapter for the implant testing was constructed to enable the condition of a proximally loosened stem. During FEM analysis, a solid model was made of the assembly. An analysis of presented results indicated good agreement of experimental and numerical research.