hrcak mascot   Srce   HID

Izvorni znanstveni članak
https://doi.org/10.15644/asc51/4/5

Utjecaj termocikliranja na čvrstoću savijanja poliamidne baze proteze

Nick Polychronakis ; Zavod za stomatološku protetiku Stomatološkog fakulteta Sveučilišta Kapodistrian, Atena, Grčka
Aspasia Sarafianou ; Zavod za mobilnu protetiku Stomatološkog fakulteta Sveučilišta Kapodistrian, Atena, Grčka
Alkibiadis Zissis ; Zavod za stomatološku protetiku Stomatološkog fakulteta Sveučilišta Kapodistrian, Atena, Grčka
Triantafillos Papadopoulos ; Zavod za biomaterijale Stomatološkog fakulteta Sveučilišta Kapodistrian, Atena, Grčka

Puni tekst: hrvatski, pdf (210 KB) str. 309-315 preuzimanja: 111* citiraj
APA 6th Edition
Polychronakis, N., Sarafianou, A., Zissis, A. i Papadopoulos, T. (2017). Utjecaj termocikliranja na čvrstoću savijanja poliamidne baze proteze. Acta stomatologica Croatica, 51 (4), 309-315. https://doi.org/10.15644/asc51/4/5
MLA 8th Edition
Polychronakis, Nick, et al. "Utjecaj termocikliranja na čvrstoću savijanja poliamidne baze proteze." Acta stomatologica Croatica, vol. 51, br. 4, 2017, str. 309-315. https://doi.org/10.15644/asc51/4/5. Citirano 25.09.2020.
Chicago 17th Edition
Polychronakis, Nick, Aspasia Sarafianou, Alkibiadis Zissis i Triantafillos Papadopoulos. "Utjecaj termocikliranja na čvrstoću savijanja poliamidne baze proteze." Acta stomatologica Croatica 51, br. 4 (2017): 309-315. https://doi.org/10.15644/asc51/4/5
Harvard
Polychronakis, N., et al. (2017). 'Utjecaj termocikliranja na čvrstoću savijanja poliamidne baze proteze', Acta stomatologica Croatica, 51(4), str. 309-315. https://doi.org/10.15644/asc51/4/5
Vancouver
Polychronakis N, Sarafianou A, Zissis A, Papadopoulos T. Utjecaj termocikliranja na čvrstoću savijanja poliamidne baze proteze. Acta stomatologica Croatica [Internet]. 2017 [pristupljeno 25.09.2020.];51(4):309-315. https://doi.org/10.15644/asc51/4/5
IEEE
N. Polychronakis, A. Sarafianou, A. Zissis i T. Papadopoulos, "Utjecaj termocikliranja na čvrstoću savijanja poliamidne baze proteze", Acta stomatologica Croatica, vol.51, br. 4, str. 309-315, 2017. [Online]. https://doi.org/10.15644/asc51/4/5
Puni tekst: engleski, pdf (210 KB) str. 309-315 preuzimanja: 96* citiraj
APA 6th Edition
Polychronakis, N., Sarafianou, A., Zissis, A. i Papadopoulos, T. (2017). The Influence of Thermocycling on the Flexural Strength of a Polyamide Denture Base Material. Acta stomatologica Croatica, 51 (4), 309-315. https://doi.org/10.15644/asc51/4/5
MLA 8th Edition
Polychronakis, Nick, et al. "The Influence of Thermocycling on the Flexural Strength of a Polyamide Denture Base Material." Acta stomatologica Croatica, vol. 51, br. 4, 2017, str. 309-315. https://doi.org/10.15644/asc51/4/5. Citirano 25.09.2020.
Chicago 17th Edition
Polychronakis, Nick, Aspasia Sarafianou, Alkibiadis Zissis i Triantafillos Papadopoulos. "The Influence of Thermocycling on the Flexural Strength of a Polyamide Denture Base Material." Acta stomatologica Croatica 51, br. 4 (2017): 309-315. https://doi.org/10.15644/asc51/4/5
Harvard
Polychronakis, N., et al. (2017). 'The Influence of Thermocycling on the Flexural Strength of a Polyamide Denture Base Material', Acta stomatologica Croatica, 51(4), str. 309-315. https://doi.org/10.15644/asc51/4/5
Vancouver
Polychronakis N, Sarafianou A, Zissis A, Papadopoulos T. The Influence of Thermocycling on the Flexural Strength of a Polyamide Denture Base Material. Acta stomatologica Croatica [Internet]. 2017 [pristupljeno 25.09.2020.];51(4):309-315. https://doi.org/10.15644/asc51/4/5
IEEE
N. Polychronakis, A. Sarafianou, A. Zissis i T. Papadopoulos, "The Influence of Thermocycling on the Flexural Strength of a Polyamide Denture Base Material", Acta stomatologica Croatica, vol.51, br. 4, str. 309-315, 2017. [Online]. https://doi.org/10.15644/asc51/4/5

Sažetak
Svrha: Svrha ovoga rada bila je procijeniti utjecaj termocikliranja na čvrstoću savijanja poliamidnog
materijala za bazu proteze. Materijali i metode: Testiran je poliamidni protezni materijal (Valplast),
a kao kontrola korišten je PMMA (Vertex). Trideset primjeraka svakog materijala izrađeno je za ispitivanje
čvrstoće savijanja prema standardu ISO 1567. Svi su uzorci pripremljeni i čuvani 48 sati u vodi
na temperaturi od 37 °C, a zatim su podijeljeni u tri jednake skupine (n = 10). Ispitivanje čvrstoće
savijanja obavljeno je odmah nakon uranjanja u vodu te nakon termocikliranja (5 °C/55 °C, 2c/min.)
poslije 3000 i 5000 ciklusa. Ispitivanje fleksibilnosti provedeno je na trima točkama u univerzalnom
stroju za testiranje na brzini križanja od 5 mm/min. Konačna čvrstoća savijanja izračunata je formulom:
FS = 3PL/2bd2. Dvosmjerna ANOVA s Tukeyjevim post hoc testom primijenjena je na razini .05
statističke značajnosti. Rezultati: tatistički značajno smanjenje čvrstoće savijanja zabilježeno je nakon
termocikliranja poslije 3000 ciklusa za PMMA-e i 5000 ciklusa za oba materijala. Čvrstoća savijanja
PMMA-e bila je značajno veća u odnosu na poliamid za sve ispitane uvjete (p < 0,05). Zaključak:
Termocikliranje je vrlo nepovoljno djelovalo na čvrstoću savijanja materijala poliamida i materijala
PMMA za bazu proteze.

Ključne riječi
zubna proteza, baza; čvrstoća na savijanje; smole, sintetičke; poliamid; najlon; materijali, testiranje

Hrčak ID: 190891

URI
https://hrcak.srce.hr/190891

[engleski]

Posjeta: 329 *