hrcak mascot   Srce   HID

Izvorni znanstveni članak
https://doi.org/10.17559/TV-20160203223352

Improved Method for Long-Term Frequency Stability Measurement Using Vector Voltmeter

Ivica Milanovic   ORCID icon orcid.org/0000-0001-7494-3755 ; Technical Test Center, Vojvode Stepe 445A, 11000 Belgrade, Serbia
Zeljko Beljic ; University of Novi Sad, Faculty of Technical Sciences, Trg Dositeja Obradovića 6, 21000 Novi Sad, Serbia
Predrag Rakonjac ; Technical Test Center, Vojvode Stepe 445A, 11000 Belgrade, Serbia
Zoran Mitrovic   ORCID icon orcid.org/0000-0001-7660-0844 ; University of Novi Sad, Faculty of Technical Sciences, Trg Dositeja Obradovića 6, 21000 Novi Sad, Serbia

Puni tekst: engleski, pdf (1 MB) str. 329-336 preuzimanja: 644* citiraj
APA 6th Edition
Milanovic, I., Beljic, Z., Rakonjac, P. i Mitrovic, Z. (2018). Improved Method for Long-Term Frequency Stability Measurement Using Vector Voltmeter. Tehnički vjesnik, 25 (2), 329-336. https://doi.org/10.17559/TV-20160203223352
MLA 8th Edition
Milanovic, Ivica, et al. "Improved Method for Long-Term Frequency Stability Measurement Using Vector Voltmeter." Tehnički vjesnik, vol. 25, br. 2, 2018, str. 329-336. https://doi.org/10.17559/TV-20160203223352. Citirano 15.05.2021.
Chicago 17th Edition
Milanovic, Ivica, Zeljko Beljic, Predrag Rakonjac i Zoran Mitrovic. "Improved Method for Long-Term Frequency Stability Measurement Using Vector Voltmeter." Tehnički vjesnik 25, br. 2 (2018): 329-336. https://doi.org/10.17559/TV-20160203223352
Harvard
Milanovic, I., et al. (2018). 'Improved Method for Long-Term Frequency Stability Measurement Using Vector Voltmeter', Tehnički vjesnik, 25(2), str. 329-336. https://doi.org/10.17559/TV-20160203223352
Vancouver
Milanovic I, Beljic Z, Rakonjac P, Mitrovic Z. Improved Method for Long-Term Frequency Stability Measurement Using Vector Voltmeter. Tehnički vjesnik [Internet]. 2018 [pristupljeno 15.05.2021.];25(2):329-336. https://doi.org/10.17559/TV-20160203223352
IEEE
I. Milanovic, Z. Beljic, P. Rakonjac i Z. Mitrovic, "Improved Method for Long-Term Frequency Stability Measurement Using Vector Voltmeter", Tehnički vjesnik, vol.25, br. 2, str. 329-336, 2018. [Online]. https://doi.org/10.17559/TV-20160203223352

Sažetak
This paper proposes a novel approach for the improvement of the long-term frequency stability measurement using an obsolete phase meter. The hypothesis of the paper states it is possible to fully automate measurement process and reduce measurement time using the standard method supported by bespoke PC software. This theory was examined in detail and experimentally validated using GPS standard method. The results of the experiment confirmed that measurement time can be reduced more than 50 %, at the expense of a measurement uncertainty increase. Still, the estimated measurement uncertainty of the proposed method is more than satisfactory for the calibration purpose of the most common oscillator types including rubidium frequency standards.

Ključne riječi
automation; frequency; long-term stability; phase angle; vector voltmeter