hrcak mascot   Srce   HID

Izvorni znanstveni članak

Transformer oil fault gases under thermal stress at 160 °C – Part I

Bernd Christian
Armin Glaeser

Puni tekst: engleski, pdf (1 MB) str. 108-115 preuzimanja: 535* citiraj
APA 6th Edition
Christian, B. i Glaeser, A. (2018). Transformer oil fault gases under thermal stress at 160 °C – Part I. Transformers Magazine, 5 (2), 108-115. Preuzeto s https://hrcak.srce.hr/202539
MLA 8th Edition
Christian, Bernd i Armin Glaeser. "Transformer oil fault gases under thermal stress at 160 °C – Part I." Transformers Magazine, vol. 5, br. 2, 2018, str. 108-115. https://hrcak.srce.hr/202539. Citirano 23.10.2020.
Chicago 17th Edition
Christian, Bernd i Armin Glaeser. "Transformer oil fault gases under thermal stress at 160 °C – Part I." Transformers Magazine 5, br. 2 (2018): 108-115. https://hrcak.srce.hr/202539
Harvard
Christian, B., i Glaeser, A. (2018). 'Transformer oil fault gases under thermal stress at 160 °C – Part I', Transformers Magazine, 5(2), str. 108-115. Preuzeto s: https://hrcak.srce.hr/202539 (Datum pristupa: 23.10.2020.)
Vancouver
Christian B, Glaeser A. Transformer oil fault gases under thermal stress at 160 °C – Part I. Transformers Magazine [Internet]. 2018 [pristupljeno 23.10.2020.];5(2):108-115. Dostupno na: https://hrcak.srce.hr/202539
IEEE
B. Christian i A. Glaeser, "Transformer oil fault gases under thermal stress at 160 °C – Part I", Transformers Magazine, vol.5, br. 2, str. 108-115, 2018. [Online]. Dostupno na: https://hrcak.srce.hr/202539. [Citirano: 23.10.2020.]

Sažetak
Dissolved gas analysis is a common technique in the supervision and maintenance of transformers. It can give hints on defects and faults in oil-immersed transformers by determining and quantifying the gases arising due to the thermal or electrical stress. Different algorithms for the assessment of transformers, which utilize data obtained from dissolved gas analysis, have been published so far. However, only few investigations exist that deal with the influence of the oil´s composition on the oil´s tendency of releasing gases. This research study presents a comparison of three commercially available transformer oils of different composition regarding that aspect. The results indicate that the oil mainly consisting of paraffinic hydrocarbons shows a different gassing pattern compared to naphthenic oils when it is exposed to thermal stress. Some explanations for this phenomenon are given in the report as well.

Ključne riječi
dissolved gas analysis; thermal stress; transformer oil; fault gases