hrcak mascot   Srce   HID

Izvorni znanstveni članak

Transformer oil fault gases under thermal stress at 160 °C – Part II

Bernd CHRISTIAN
Armin GLÄSER

Puni tekst: engleski, pdf (606 KB) str. 26-35 preuzimanja: 98* citiraj
APA 6th Edition
CHRISTIAN, B. i GLÄSER, A. (2018). Transformer oil fault gases under thermal stress at 160 °C – Part II. Transformers Magazine, 5 (3), 26-35. Preuzeto s https://hrcak.srce.hr/207736
MLA 8th Edition
CHRISTIAN, Bernd i Armin GLÄSER. "Transformer oil fault gases under thermal stress at 160 °C – Part II." Transformers Magazine, vol. 5, br. 3, 2018, str. 26-35. https://hrcak.srce.hr/207736. Citirano 02.12.2020.
Chicago 17th Edition
CHRISTIAN, Bernd i Armin GLÄSER. "Transformer oil fault gases under thermal stress at 160 °C – Part II." Transformers Magazine 5, br. 3 (2018): 26-35. https://hrcak.srce.hr/207736
Harvard
CHRISTIAN, B., i GLÄSER, A. (2018). 'Transformer oil fault gases under thermal stress at 160 °C – Part II', Transformers Magazine, 5(3), str. 26-35. Preuzeto s: https://hrcak.srce.hr/207736 (Datum pristupa: 02.12.2020.)
Vancouver
CHRISTIAN B, GLÄSER A. Transformer oil fault gases under thermal stress at 160 °C – Part II. Transformers Magazine [Internet]. 2018 [pristupljeno 02.12.2020.];5(3):26-35. Dostupno na: https://hrcak.srce.hr/207736
IEEE
B. CHRISTIAN i A. GLÄSER, "Transformer oil fault gases under thermal stress at 160 °C – Part II", Transformers Magazine, vol.5, br. 3, str. 26-35, 2018. [Online]. Dostupno na: https://hrcak.srce.hr/207736. [Citirano: 02.12.2020.]

Sažetak
Dissolved gas analysis is a common technique in the supervision and maintenance of transformers. It can give hints on defects and faults in oil-immersed transformers by determining and quantifying gases arising due to thermal or electrical stress. Different algorithms for the assessment of transformers, which deploy data obtained from dissolved gas analysis, have been published so far. However, only few investigations exist that deal with the influence of the oil’s chemical composition towards the oil’s tendency of releasing gases. This research study uses a closed experimental set-up, which only exchanges energy with the environment, to compare four commercially available transformer oils of different composition in regard to that aspect. The results indicate that an oil mainly consisting of paraffinic hydrocarbons shows a different gassing pattern compared to naphthenic oils when it is exposed to thermal stress. Some explanations for this phenomenon are given in the report as well.

Ključne riječi
dissolved gas analysis; thermal stress; transformer oil; fault gases