hrcak mascot   Srce   HID

Izvorni znanstveni članak
https://doi.org/10.17559/TV-20190307132215

Using a FACTS Device as a Power Conditioner Suitable for Dynamic Reactive Power Compensation in Railway Application

Josip Pavleka* ; HEP-Distribution System Operator Ltd., Ulica grada Vukovara 37, 10000 Zagreb, Croatia
Srete Nikolovski   ORCID icon orcid.org/0000-0002-9033-4332 ; Faculty of Electrical Engineering, Computer Science and Information Technology Osijek, Kneza Trpimira 2b, 31000 Osijek, Croatia
Anton Marušić ; HEP-Distribution System Operator Ltd., Ulica grada Vukovara 37, 10000 Zagreb, Croatia

Puni tekst: engleski, pdf (2 MB) str. 1686-1693 preuzimanja: 12* citiraj
APA 6th Edition
Pavleka*, J., Nikolovski, S. i Marušić, A. (2019). Using a FACTS Device as a Power Conditioner Suitable for Dynamic Reactive Power Compensation in Railway Application. Tehnički vjesnik, 26 (6), 1686-1693. https://doi.org/10.17559/TV-20190307132215
MLA 8th Edition
Pavleka*, Josip, et al. "Using a FACTS Device as a Power Conditioner Suitable for Dynamic Reactive Power Compensation in Railway Application." Tehnički vjesnik, vol. 26, br. 6, 2019, str. 1686-1693. https://doi.org/10.17559/TV-20190307132215. Citirano 06.12.2019.
Chicago 17th Edition
Pavleka*, Josip, Srete Nikolovski i Anton Marušić. "Using a FACTS Device as a Power Conditioner Suitable for Dynamic Reactive Power Compensation in Railway Application." Tehnički vjesnik 26, br. 6 (2019): 1686-1693. https://doi.org/10.17559/TV-20190307132215
Harvard
Pavleka*, J., Nikolovski, S., i Marušić, A. (2019). 'Using a FACTS Device as a Power Conditioner Suitable for Dynamic Reactive Power Compensation in Railway Application', Tehnički vjesnik, 26(6), str. 1686-1693. https://doi.org/10.17559/TV-20190307132215
Vancouver
Pavleka* J, Nikolovski S, Marušić A. Using a FACTS Device as a Power Conditioner Suitable for Dynamic Reactive Power Compensation in Railway Application. Tehnički vjesnik [Internet]. 2019 [pristupljeno 06.12.2019.];26(6):1686-1693. https://doi.org/10.17559/TV-20190307132215
IEEE
J. Pavleka*, S. Nikolovski i A. Marušić, "Using a FACTS Device as a Power Conditioner Suitable for Dynamic Reactive Power Compensation in Railway Application", Tehnički vjesnik, vol.26, br. 6, str. 1686-1693, 2019. [Online]. https://doi.org/10.17559/TV-20190307132215

Sažetak
The paper presents advantages of dynamic reactive power compensation facilities instead of until now used fixed compensation, as a standard technical solution in railway. Short overview of theory in the field of FACTS device is given. Simulations of these systems have been successfully developed in the MATLAB Simulink program. Recommendation is given for some of main parts in plant design. Results of simulation were proven through the measurement, which was done. Finally, the impact of reactive power compensation using FACTS device on the stability of the EPS (Electrical Power System) voltage was evaluated. Significantly, reduced cost has been shown for over-consumed reactive energy.

Ključne riječi
cost reduction; FACTS (Flexible AC Transmission System); MATLAB Simulink Model; power conditioning; reactive power compensation; simulation

Hrčak ID: 228516

URI
https://hrcak.srce.hr/228516

Posjeta: 22 *