Skoči na glavni sadržaj

Izvorni znanstveni članak

https://doi.org/10.2478/acph-2020-0036

HPLC method development for fampridine using Analytical Quality by Design approach

BÉLA KOVÁCS ; Gedeon Richter Romania, 540306, Tîrgu Mureș, Romania, Department of Biochemistry and the Chemistry of Environmental Factors, Faculty of Pharmacy University of Medicine, Pharmacy, Science and Technology of Tîrgu Mureș, 540139, Tîrgu Mureș, Romania
FRANCISC BODA ; Department of General and Inorganic Chemistry, Faculty of Pharmacy, University of Medicine, Pharmacy, Science and Technology of Tîrgu Mureș, 540139, Tîrgu Mureș, Romania
IBOLYA FÜLÖP ; Department of Toxicology and Biopharmacy, Faculty of Pharmacy, University of Medicine, Pharmacy, Science and Technology of Tîrgu Mureș, 540139, Tîrgu Mureș, Romania
ISTVÁN SZÉKELY-SZENTMIKLÓSI ; Gedeon Richter Romania, 540306, Tîrgu Mureș, Romania; Department of Pharmaceutical Industry and Management, Faculty of Pharmacy, University of Medicine, Pharmacy, Science and Technology of Tîrgu Mureș, 540139, Tîrgu Mureș, Romania
ÉVA KATALIN KELEMEN ; Gedeon Richter Romania, 540306, Tîrgu Mureș, Romania
BOGLÁRKA KOVÁCS-DEÁK ; Department of Biochemistry and the Chemistry of Environmental Factors, Faculty of Pharmacy University of Medicine, Pharmacy, Science and Technology of Tîrgu Mureș, 540139, Tîrgu Mureș, Romania
BLANKA SZÉKELY-SZENTMIKLÓSI ; Department of Pharmaceutical Chemistry, Faculty of Pharmacy, University of Medicine, Pharmacy, Science and Technology of Tîrgu Mureș, 540139, Tîrgu Mureș, Romania


Puni tekst: engleski pdf 633 Kb

str. 465-482

preuzimanja: 653

citiraj


Sažetak

Offering a systematic and multivariate analysis of the analytical procedure, development and validation of HPLC methods using Quality by Design approach are in the limelight of current research trends. A new, experimental design-aided HPLC method for fampridine was developed and preliminarily validated according to current in-force international guidelines for linearity, accuracy, robustness and precision.
The method offers a high throughput sample analysis, with an elution time of 2.9 minutes, and signal detection without excipient interference performed at 262 nm. The method proved to be linear between 1–15 µg mL–1 (R2 = 0.9996). The mean recovery was found to be 98.7 ± 1.9 % in the tested range of 2.5–7.5 µg mL–1. Low RSD values (< 1 %) were obtained for both model, intra- and inter-day precision. The limit of detection and limit of quantification were 0.24 and 0.78 µg mL–1, resp. The method proved to be applicable for active substance assay in a pharmaceutical dosage form.

Ključne riječi

Analytical Quality by Design; fampridine; HPLC

Hrčak ID:

233117

URI

https://hrcak.srce.hr/233117

Datum izdavanja:

31.12.2020.

Posjeta: 1.310 *