hrcak mascot   Srce   HID

Izvorni znanstveni članak

The reliability and sensitivity of indices related to cardiovascular fitness evaluation

Yuan Jinzhou ; Department of Exercise Science, Xi‘an Physical Education University, Xi‘an, China
Yibing Fu ; Shandong Provincial Hospital, Shandong University, China
Ruipeng Zhang ; Shannxi Institute of Technology, Shannxi, China
Xi Li ; Department of Kinesiology, University of Lethbridge, Alberta, Canada
Gongbing Shan ; Department of Kinesiology, University of Lethbridge, Alberta, Canada

Puni tekst: engleski, pdf (141 KB) str. 139-146 preuzimanja: 1.974* citiraj
APA 6th Edition
Jinzhou, Y., Fu, Y., Zhang, R., Li, X. i Shan, G. (2008). The reliability and sensitivity of indices related to cardiovascular fitness evaluation. Kinesiology, 40 (2), 139-146. Preuzeto s https://hrcak.srce.hr/30813
MLA 8th Edition
Jinzhou, Yuan, et al. "The reliability and sensitivity of indices related to cardiovascular fitness evaluation." Kinesiology, vol. 40, br. 2, 2008, str. 139-146. https://hrcak.srce.hr/30813. Citirano 08.12.2019.
Chicago 17th Edition
Jinzhou, Yuan, Yibing Fu, Ruipeng Zhang, Xi Li i Gongbing Shan. "The reliability and sensitivity of indices related to cardiovascular fitness evaluation." Kinesiology 40, br. 2 (2008): 139-146. https://hrcak.srce.hr/30813
Harvard
Jinzhou, Y., et al. (2008). 'The reliability and sensitivity of indices related to cardiovascular fitness evaluation', Kinesiology, 40(2), str. 139-146. Preuzeto s: https://hrcak.srce.hr/30813 (Datum pristupa: 08.12.2019.)
Vancouver
Jinzhou Y, Fu Y, Zhang R, Li X, Shan G. The reliability and sensitivity of indices related to cardiovascular fitness evaluation. Kinesiology [Internet]. 2008 [pristupljeno 08.12.2019.];40(2):139-146. Dostupno na: https://hrcak.srce.hr/30813
IEEE
Y. Jinzhou, Y. Fu, R. Zhang, X. Li i G. Shan, "The reliability and sensitivity of indices related to cardiovascular fitness evaluation", Kinesiology, vol.40, br. 2, str. 139-146, 2008. [Online]. Dostupno na: https://hrcak.srce.hr/30813. [Citirano: 08.12.2019.]

Sažetak
Determining the recovery heart rate (RHR) index after various submaximal exercises is a popular and practical way for a population’s cardiovascular fitness evaluation. These evaluations are based on the regression among RHR, load intensity, and maximal oxygen uptake. However, little work has been done to 1) explore the influences of body weight and height on these tests’ reliability and sensitivity, and 2) compare the reliability among the tests. As a result, practitioners often choose tests without the appropriate criteria. This study researched the mentioned two aspects by evaluating 30 male college students via three common tests – 30 cm step test, 40 cm step test and squat-up-down test. The results showed that the reliability and sensitivity of the three tests were remarkably different. Adding body weight into the evaluation would improve both reliability and sensitivity. Considering all the influence factors, 30 cm step test was the best one. These findings suggested that applying the relative RHR index (normalized by body weight) should be considered for a population’s cardiovascular fitness evaluation in the future.

Ključne riječi
reliability; sensitivity; cardiovascular fitness test; relative indices; comparison

Hrčak ID: 30813

URI
https://hrcak.srce.hr/30813

[hrvatski]

Posjeta: 2.662 *