Analysis of Exergy Destruction of an Evaporator or/and a Condenser

Antun GALOVIĆ ; Faculty of Mechanical Engineering and Naval Architecture, University of Zagreb, Zagreb, Croatia
Marija ŽIVIĆ ; Faculty of Mechanical Engineering, J.J. Strossmayer University of Osijek, Slavonski brod, Croatia
Mato KOKANOVIĆ ; Faculty of Mechanical Engineering, J.J. Strossmayer University of Osijek, Slavonski brod, Croatia

Puni tekst: engleski, pdf (1 MB) str. 73-78 preuzimanja: 2.333* citiraj
APA 6th Edition
GALOVIĆ, A., ŽIVIĆ, M. i KOKANOVIĆ, M. (2009). Analysis of Exergy Destruction of an Evaporator or/and a Condenser. Strojarstvo, 51 (1), 73-78. Preuzeto s https://hrcak.srce.hr/42850
MLA 8th Edition
GALOVIĆ, Antun, et al. "Analysis of Exergy Destruction of an Evaporator or/and a Condenser." Strojarstvo, vol. 51, br. 1, 2009, str. 73-78. https://hrcak.srce.hr/42850. Citirano 19.10.2021.
Chicago 17th Edition
GALOVIĆ, Antun, Marija ŽIVIĆ i Mato KOKANOVIĆ. "Analysis of Exergy Destruction of an Evaporator or/and a Condenser." Strojarstvo 51, br. 1 (2009): 73-78. https://hrcak.srce.hr/42850
Harvard
GALOVIĆ, A., ŽIVIĆ, M., i KOKANOVIĆ, M. (2009). 'Analysis of Exergy Destruction of an Evaporator or/and a Condenser', Strojarstvo, 51(1), str. 73-78. Preuzeto s: https://hrcak.srce.hr/42850 (Datum pristupa: 19.10.2021.)
Vancouver
GALOVIĆ A, ŽIVIĆ M, KOKANOVIĆ M. Analysis of Exergy Destruction of an Evaporator or/and a Condenser. Strojarstvo [Internet]. 2009 [pristupljeno 19.10.2021.];51(1):73-78. Dostupno na: https://hrcak.srce.hr/42850
IEEE
A. GALOVIĆ, M. ŽIVIĆ i M. KOKANOVIĆ, "Analysis of Exergy Destruction of an Evaporator or/and a Condenser", Strojarstvo, vol.51, br. 1, str. 73-78, 2009. [Online]. Dostupno na: https://hrcak.srce.hr/42850. [Citirano: 19.10.2021.]

Sažetak
This paper presents the exergy destruction of an evaporator or a condenser or evaporator and condenser. The exergy destruction can be analytically calculated by using the same non-dimensional variables which have been used by its energy analysis. The one additional variable is the ratio of absolute input temperatures of both streams. This means that the given model enables the simultaneous calculation of heat transfer effectiveness and exergy destruction respectively. The exergy destruction is put in the ratio to the heat capacity of the weaker stream. The limited values of the exergy destruction are estimated, taking into account the zero and infinite values of relevant variables. Further, exergy destruction for the case when both streams change phase is calculated, which means that the appropriate heat exchanger is condenser and evaporator simultaneously. The given model is derived as a special case of the model for calculation of exergy destruction by parallel and counter flow heat exchangers respectively.
For all presented cases the only temperature differences between the streams have been taken into account. This means that the effect of a frictional pressure drop of the streams on exergy destruction has been neglected.

Ključne riječi
Condenser; Evaporator; Evaporator and condenser; Exergy destruction

Hrčak ID: 42850

URI
https://hrcak.srce.hr/42850

Posjeta: 3.001 *