hrcak mascot   Srce   HID

Izvorni znanstveni članak
https://doi.org/10.2498/cit.1001126

A Patient-specific Knee Joint Computer Model Using MRI Data and 'in vivo' Compressive Load from the Optical Force Measuring System

Denis Donlagic
Boris Cigale
Dusan Heric
Edvard Cibula
Damjan Zazula
Bozidar Potocnik

Puni tekst: engleski, pdf (1021 KB) str. 209-222 preuzimanja: 1.065* citiraj
APA 6th Edition
Donlagic, D., Cigale, B., Heric, D., Cibula, E., Zazula, D. i Potocnik, B. (2008). A Patient-specific Knee Joint Computer Model Using MRI Data and 'in vivo' Compressive Load from the Optical Force Measuring System. Journal of computing and information technology, 16 (3), 209-222. https://doi.org/10.2498/cit.1001126
MLA 8th Edition
Donlagic, Denis, et al. "A Patient-specific Knee Joint Computer Model Using MRI Data and 'in vivo' Compressive Load from the Optical Force Measuring System." Journal of computing and information technology, vol. 16, br. 3, 2008, str. 209-222. https://doi.org/10.2498/cit.1001126. Citirano 27.10.2020.
Chicago 17th Edition
Donlagic, Denis, Boris Cigale, Dusan Heric, Edvard Cibula, Damjan Zazula i Bozidar Potocnik. "A Patient-specific Knee Joint Computer Model Using MRI Data and 'in vivo' Compressive Load from the Optical Force Measuring System." Journal of computing and information technology 16, br. 3 (2008): 209-222. https://doi.org/10.2498/cit.1001126
Harvard
Donlagic, D., et al. (2008). 'A Patient-specific Knee Joint Computer Model Using MRI Data and 'in vivo' Compressive Load from the Optical Force Measuring System', Journal of computing and information technology, 16(3), str. 209-222. https://doi.org/10.2498/cit.1001126
Vancouver
Donlagic D, Cigale B, Heric D, Cibula E, Zazula D, Potocnik B. A Patient-specific Knee Joint Computer Model Using MRI Data and 'in vivo' Compressive Load from the Optical Force Measuring System. Journal of computing and information technology [Internet]. 2008 [pristupljeno 27.10.2020.];16(3):209-222. https://doi.org/10.2498/cit.1001126
IEEE
D. Donlagic, B. Cigale, D. Heric, E. Cibula, D. Zazula i B. Potocnik, "A Patient-specific Knee Joint Computer Model Using MRI Data and 'in vivo' Compressive Load from the Optical Force Measuring System", Journal of computing and information technology, vol.16, br. 3, str. 209-222, 2008. [Online]. https://doi.org/10.2498/cit.1001126

Sažetak
Modelling of patient knee joint from the MRI data and simulating its kinematics is presented. A flexion of the femur with respect to the tibia from $\\\\rm{0^o}$ to around $\\\\rm{40^o}$ is simulated. The finite element knee model is driven by compressive load measured \\\'in vivo\\\' during MRI process by using specially developed optical force measurement system. Predicted kinematics is
evaluated against the high-quality model obtained by registration from experimentally gathered low-quality MRI at fixed flexions.
Validation pointed out that the mean square error (MSE) for the Euler rotation angles are bellow $\\\\rm{1.73^o}$, while the MSE for
Euler translation is smaller than 5.93 mm.

Hrčak ID: 44594

URI
https://hrcak.srce.hr/44594

Posjeta: 1.295 *