hrcak mascot   Srce   HID

Original scientific paper

Učinci adheziva osjetljivih na tlak i kemijskih promotora na permeaciju fentanila kroz kožu štakora

AMIR MEHDIZADEH
MOHAMMAD HOSSAIN GHAHREMANI
MOHAMMAD REZA ROUINI
TAYEBEH TOLIYAT

Fulltext: english, pdf (84 KB) pages 219-229 downloads: 1.280* cite
APA 6th Edition
MEHDIZADEH, A., GHAHREMANI, M.H., ROUINI, M.R. & TOLIYAT, T. (2006). Effects of pressure sensitive adhesives and chemical permeation enhancers on permeability of fentanyl through excised rat skin. Acta Pharmaceutica, 56 (2), 219-229. Retrieved from https://hrcak.srce.hr/4557
MLA 8th Edition
MEHDIZADEH, AMIR, et al. "Effects of pressure sensitive adhesives and chemical permeation enhancers on permeability of fentanyl through excised rat skin." Acta Pharmaceutica, vol. 56, no. 2, 2006, pp. 219-229. https://hrcak.srce.hr/4557. Accessed 21 Jul. 2019.
Chicago 17th Edition
MEHDIZADEH, AMIR, MOHAMMAD HOSSAIN GHAHREMANI, MOHAMMAD REZA ROUINI and TAYEBEH TOLIYAT. "Effects of pressure sensitive adhesives and chemical permeation enhancers on permeability of fentanyl through excised rat skin." Acta Pharmaceutica 56, no. 2 (2006): 219-229. https://hrcak.srce.hr/4557
Harvard
MEHDIZADEH, A., et al. (2006). 'Effects of pressure sensitive adhesives and chemical permeation enhancers on permeability of fentanyl through excised rat skin', Acta Pharmaceutica, 56(2), pp. 219-229. Available at: https://hrcak.srce.hr/4557 (Accessed 21 July 2019)
Vancouver
MEHDIZADEH A, GHAHREMANI MH, ROUINI MR, TOLIYAT T. Effects of pressure sensitive adhesives and chemical permeation enhancers on permeability of fentanyl through excised rat skin. Acta Pharm. [Internet]. 2006 [cited 2019 July 21];56(2):219-229. Available from: https://hrcak.srce.hr/4557
IEEE
A. MEHDIZADEH, M.H. GHAHREMANI, M.R. ROUINI and T. TOLIYAT, "Effects of pressure sensitive adhesives and chemical permeation enhancers on permeability of fentanyl through excised rat skin", Acta Pharmaceutica, vol.56, no. 2, pp. 219-229, 2006. [Online]. Available: https://hrcak.srce.hr/4557. [Accessed: 21 July 2019]

Abstracts
Pripravljeni su transdermalni adhezivni flasteri fentanila (DIAPs) koristeći različite adhezive osjetljivih na tlak (PSAs) i kemijske promotore permeabilnosti (CPEs). Njihovi učinci na permeabilnost fentanila evaluirani su pomoću modificirane Franzove difuzijske ćelije s membranom od kože s abdomena štakora. Brzina permeabilnosti (Jss) ovisi o viskoznosti i vrsti akrilnih adheziva i o vrsti promotora. Najveća vrijednost Jss = 1,95 μg cm-2 h-1 postignuta je s Duro-Tak® 2054, a najmanja (Jss = 1,43 μg cm-2 h-1) s Duro-Tak® 2516. Među različitim promotorima propilen glikol i polietilen glikol 400 pokazali su najveći (1,61) i najmanji (1,18) omjer poboljšanja (ER) permeabilnosti. Oleinska kiselina i cetil alkohol umjereno su povećali permeabilnost fentanila. Za mjerenje adhezivnih svojstava upotrebljena je "metoda ljuštenja". Povećanje koncentracije CPE smanjilo je adhezivna svojstva PSA. Kada je udio fentanila u flasteru povišen s 1 na 3%, brzina permeabilnosti se povećala, dok daljnje povećanje udjela fentanila nije značajno utjecalo na brzinu. Pripravak s 10% propilen glikola i 3% fentanila u Duro-Tak 2054 pokazao se kao učinkoviti transdermalni terapijski sustav za fentanil.

Keywords
fentanil; promotor permeabilnosti; transdermalni flasteri; adhezivi osjetljivi na tlak; koža štakora

Hrčak ID: 4557

URI
https://hrcak.srce.hr/4557

[english]

Visits: 1.994 *