hrcak mascot   Srce   HID

Pregledni rad

STANDARDISATION OF OPTOTYPES

ZDENKO BUJGER
JASENKA PIČMAN
ANDREJA LUKENDA
IGOR PETRIČEK

Puni tekst: hrvatski, pdf (112 KB) str. 252-256 preuzimanja: 2.191* citiraj
APA 6th Edition
BUJGER, Z., PIČMAN, J., LUKENDA, A. i PETRIČEK, I. (2010). STANDARDIZACIJA OPTOTIPA. Liječnički vjesnik, 132 (7-8), 252-256. Preuzeto s https://hrcak.srce.hr/63592
MLA 8th Edition
BUJGER, ZDENKO, et al. "STANDARDIZACIJA OPTOTIPA." Liječnički vjesnik, vol. 132, br. 7-8, 2010, str. 252-256. https://hrcak.srce.hr/63592. Citirano 14.10.2019.
Chicago 17th Edition
BUJGER, ZDENKO, JASENKA PIČMAN, ANDREJA LUKENDA i IGOR PETRIČEK. "STANDARDIZACIJA OPTOTIPA." Liječnički vjesnik 132, br. 7-8 (2010): 252-256. https://hrcak.srce.hr/63592
Harvard
BUJGER, Z., et al. (2010). 'STANDARDIZACIJA OPTOTIPA', Liječnički vjesnik, 132(7-8), str. 252-256. Preuzeto s: https://hrcak.srce.hr/63592 (Datum pristupa: 14.10.2019.)
Vancouver
BUJGER Z, PIČMAN J, LUKENDA A, PETRIČEK I. STANDARDIZACIJA OPTOTIPA. Liječnički vjesnik [Internet]. 2010 [pristupljeno 14.10.2019.];132(7-8):252-256. Dostupno na: https://hrcak.srce.hr/63592
IEEE
Z. BUJGER, J. PIČMAN, A. LUKENDA i I. PETRIČEK, "STANDARDIZACIJA OPTOTIPA", Liječnički vjesnik, vol.132, br. 7-8, str. 252-256, 2010. [Online]. Dostupno na: https://hrcak.srce.hr/63592. [Citirano: 14.10.2019.]

Sažetak
Optotypes are signs of different sizes, systematically placed on the visual acuity chart. The human eye has a spatial resolution of 1’ of arc (Snellen). Optotypes in the basic row on all charts subtend 5’ of arc and their detail 1’ of arc, from the testing distance. The disadvantage of all classical charts is the irregular progresssion of optotype sizes in adjacent rows. This was solved by logMAR (Bailey-Lovie) chart in 1976. The chart was made with optotype sizes in steps with a constant ratio 1: 1.2589 (geometric progression). This chart has become the standard for visual acuity testing worldwide. It has been recommended by the following bodies: International Council of Ophthalmology (ICO), 1984 and 2002; World Health Organisation (WHO), 2003; International Organisation for Standardisation (ISO) 1996, and Croatian Standard Insitute homologised the ISO standard as nHRN EN ISO 8596:1996. For normative, medical and practical reasons it is advised that all school medicine, occupational health and ophthalmology departments adopt the logMAR charts system.

Ključne riječi
Visual acuity; Vision tests – standards

Hrčak ID: 63592

URI
https://hrcak.srce.hr/63592

[hrvatski]

Posjeta: 2.744 *